544K Kayak Pumps
Stainless steel piston rod for strength and durability. Comes with pump float. Lifetime warranty.
13 1/2" Kayak Pump with float
|
33.71 |
|
|
Roper Pump 18AM02-2B A Series Gear Pump W/Rv
Ports: 3/8 in.
Flow-Rate: 7.2 GPM
Max RPM: 3600
GPR: .002
Mtg: Flange
Roper A Series pumps are adaptable to a wide range of applications pumping clean ?uids, such as pressure lubrication, hydraulic service, fuel supply or general liquid transfer.
These pumps are designed to operate at standard motor speeds, with provisions for ?ange or foot mounting. The internal bearings are lubricated by the ?uid being pumped. With only two moving parts, the pumps run quietly.
3/8" and 3/4" pumps are 300 PSI and all 1 1/4" - 2" pumps are 150 PSI
Specifications
Type of Pump: Positive Displacement Gear Pump
Materials of Construction: Cast Iron Housing, Ductile Iron Gears and Drive Shafts, Bronze Bearings and Steel Idler Shafts.
Priming: Self Priming
Seal Material: Mechanical Seal (AM)
Viscosity: Up to 2,200 cSt, 10,000 SSU
|
770.40 |
|
|
Pumpguard In-Line Strainer - 1/2" NPT Port
Handy filter keeps tank crud out of your pressure water pump or bilge pump. Stainless mesh screen collects rust and scale, and can be cleaned in minutes. Protects the pump from valve damage. Can be installed in any position prior to the pump. Clear inspection cover lets you see if it needs cleaning.
Prevents dirt from entering pump intake. Works in any position. Easy to install and clean. Has transparent housing and stainless steel mesh filtering screen. Jabsco Pumpguard in-line strainers make great filtering agent.
WARNING: This product can expose you to chemicals including STYRENE which is known to the State of California to cause cancer. For more information go to P65Warnings.ca.gov.
|
24.30 |
|
|
Pumpguard In-Line Strainer - 1/2" NPT
Handy filter keeps tank crud out of your pressure water pump or bilge pump. Stainless mesh screen collects rust and scale, and can be cleaned in minutes. Protects the pump from valve damage. Can be installed in any position prior to the pump. Clear inspection cover lets you see if it needs cleaning.
Accommodations: For 1/2" Line
For Use With: In-Line
Material: Plastic & Stainless Screen
Type: Strainer
WARNING: This product can expose you to chemicals including FORMALDEHYDE (GAS) which is known to the State of California to cause cancer. For more information go to P65Warnings.ca.gov.
|
24.30 |
|
|
Sherwood R-30-G-1 WESTERBEKE PUMP
For Westerbeke 6 Cylinder Diesel 24102
Pump Body: Bronze
Ports: 1/2" NPT
Cam: Full
Impeller: Neoprene
Shaft Seal: Mechanical
Drive: Pulley Driven Pedestal Pump
|
939.20 |
|
|
MP Pump 50416 Swx125Pmp B:1/2-3 56J 3.25
|
766.43 |
|
|
Coiled Wash Down Hose - 25' - 1/2" Diameter
Features:
Parable with all Aqua Jet Washdown Pumps
25' hose length
1/2" hose diameter
|
31.85 |
|
|
Oberdorfer N991-32-C82-W Brz Gear Pump W/12/24V Mtr
|
1896.34 |
|
|
Walbro FRB-13-2 Fuel Pump 6-8 Psi 12V
Pressure: 6.0 - 8.0 psi
Service Life: 18,000+ hr
Magnetic Trap: Yes
Minimum Flow Rate: 43 gph
Dry Lift: 48"
Current Draw: 2.3 Amp
Inlet/Outlet: 1/4-18 NPSF
Fuse: 5A
Inlet Filter Screen: 70 Micron
Weight: 1.83 lb
Voltage: 12V DC
Outlet Check Valve: None
The FRB is an advanced electric fuel pump with internal circuitry allowing it to operate at a variable frequency.
When turned on, it will cycle as long as there is a demand for fuel, but when fuel demand decreases, the pump slows down as it builds pressure in the fuel delivery line - until the pump's rated maximum pressure is reached, and the pump stops.
These FRB pumps are especially suitable for applications where battery life, low noise, and best durability are important.
Not recommended for applications such as heater or stove systems as output pressures are too high.
For heater and stove fuel pumps, use the lower pressure Walbro FRD Series. See Related Products, below.
The FRB is designed to serve as a primary pump (replacing a mechanical fuel pump) or as an auxilliary fuel pump (assisting the existing pump) for internal combustion engines.
A common application is supplying fuel to the those diesel refrigeration units mounted high on tractor-trailer trucks.
These pumps incorporate a new piston mechanism which, unlike rubber diaphragms, is not affected by modern, high-tech fuel blends.
• Pump cycles only when fuel is demanded - so the pump cycles on and off
• The non-adjustable maximum output pressure is factory pre-set in the ranges specified in the table, below
• Continuous duty life (diesel fuel): >18,000 hours
• Can run dry for up to 4 hours
• Flow rates as high as 60 gph, but 30 gph is a more typical maximum
• Compatible with all commercially available pump grade gasoline, gasoline-alcohol blends, diesel, and bio-diesel fuels
• Self-priming to 4 feet
• Current draw averages less than 2 amps
• USCG 16623-1 and 16623-2 approved; ignition protected
• Anodized, corrosion protection coating passes 1,000 hr salt spray test - suitable for marine applications
• Replaceable internal 70 micron mesh filter
• Magnetic trap for ferrous contaminants
• Inlet (lower, side)/Outlet (top): 1/4-18 NPSF (Dryseal American National Standard Straight Pipe Thread) — will accept NPT tapered fittings without leaking, thread sealant recommended
• Dimensions: 5.83"H x 2.76"Dia.
• Note - a suffix number (typically -1 or -2) in part number refers to type of packaging
• Made in USA
NOTE — Although the included instructions indicate that FRB pumps are supplied with hose clamps, at this time (5/8/13), these pumps do not include any installation fittings.
Technical
Selecting among the Walbro FR Series electric fuel pumps:
• All the FR electric pumps provide fuel until the fuel demand decreases, or flow is restricted - but they have different mechanisms for doing so.
FR pumps will cycle (pump) until they build up the pressure (head) in the outflow line - with an accompanying decrease in fuel flow - and reach their factory preset maximum pressure.
At this point, constant frequency pumps like the FRA will continue cycling - but no fuel will flow.
Variable frequency pumps, like the FRB and FRD, will slow and eventually stop cycling as the pressure builds.
If the pressure on the outflow side of the pump drops, both types of pump will start supplying fuel again.
• Choosing an FR Series pump is often less dependent on the application, and more a matter of user preference:
— FRA pumps are lower cost, basic models.
They have no built-in filter, and their constant cycling means electric current draw is constant - regardless of output, they are always making noise, they typically have a shorter lifespan (higher wear), and they can wear unevenly as the stroke can be shortened when operating near their maximal pressure.
— FRB and FRD pumps have a more expensive variable frequency circuit board, always use their full stroke length - so wear is evenly distributed, do not always operate at full capacity/maximal cycling — so less wear, longer life, less noise, and lower average current draw.
Additionally, the FRB models include a built-in/replaceable 70 micron mesh filter, so the user doesn't need to supply a pre-filter.
• What the FR fuel pump is designed to do:
— In carbureted applications - The FRA and FRB fuel pumps self-regulate to their maximum output pressure when the carburetor bowl is full, and respond to float movement in the carburetor as required.
When the engine demands more fuel, the pump increases its flow rate.
When the engine demand drops, the pump reduces its flow rate.
— In diesel applications - The FRA and FRB pumps will deliver fuel to the diesel injector pump, assuring a positive pressure at the injector pump inlet.
These pumps are designed to refill diesel filters after service or replacement.
— In transfer applications, including fuel polishing, FRA and FRB pumps run continuously, as long as electrical power is supplied to the pump, and output back pressure is low.
— In diesel heater and stove applications, the task-specific FRD pumps will slow their cycling rate to deliver only the fuel required by the stove fuel metering valve ("carburetor").
FRD pumps can also fill day tanks in gravity feed installations.
• Complete list of approved fuels for FR pumps:
— Unleaded regular gasoline, premium gasoline, gasoline-alcohol blends, diesel fuel, bio-diesel, Stoddard solvent, E85.
|
256.31 |
|
|
Walbro FRB-16-2 24V Fuel Pump 6-8 Psi
Outlet Check Valve: None
Voltage: 24V DC
Weight: 1.83 lb
Magnetic Trap: Yes
Minimum Flow Rate: 43 gph
Dry Lift: 48"
Current Draw: 1.7 Amp
Inlet/Outlet: 1/4-18 NPSF
Fuse: 5A
Inlet Filter Screen: 70 Micron
Service Life: 18,000+ hr
Pressure: 6.0 - 8.0 psi
The FRB is an advanced electric fuel pump with internal circuitry allowing it to operate at a variable frequency.
When turned on, it will cycle as long as there is a demand for fuel, but when fuel demand decreases, the pump slows down as it builds pressure in the fuel delivery line - until the pump's rated maximum pressure is reached, and the pump stops.
These FRB pumps are especially suitable for applications where battery life, low noise, and best durability are important.
Not recommended for applications such as heater or stove systems as output pressures are too high.
For heater and stove fuel pumps, use the lower pressure Walbro FRD Series. See Related Products, below.
The FRB is designed to serve as a primary pump (replacing a mechanical fuel pump) or as an auxilliary fuel pump (assisting the existing pump) for internal combustion engines.
A common application is supplying fuel to the those diesel refrigeration units mounted high on tractor-trailer trucks.
These pumps incorporate a new piston mechanism which, unlike rubber diaphragms, is not affected by modern, high-tech fuel blends.
• Pump cycles only when fuel is demanded - so the pump cycles on and off
• The non-adjustable maximum output pressure is factory pre-set in the ranges specified in the table, below
• Continuous duty life (diesel fuel): >18,000 hours
• Can run dry for up to 4 hours
• Flow rates as high as 60 gph, but 30 gph is a more typical maximum
• Compatible with all commercially available pump grade gasoline, gasoline-alcohol blends, diesel, and bio-diesel fuels
• Self-priming to 4 feet
• Current draw averages less than 2 amps
• USCG 16623-1 and 16623-2 approved; ignition protected
• Anodized, corrosion protection coating passes 1,000 hr salt spray test - suitable for marine applications
• Replaceable internal 70 micron mesh filter
• Magnetic trap for ferrous contaminants
• Inlet (lower, side)/Outlet (top): 1/4-18 NPSF (Dryseal American National Standard Straight Pipe Thread) — will accept NPT tapered fittings without leaking, thread sealant recommended
• Dimensions: 5.83"H x 2.76"Dia.
• Note - a suffix number (typically -1 or -2) in part number refers to type of packaging
• Made in USA
NOTE — Although the included instructions indicate that FRB pumps are supplied with hose clamps, at this time (5/8/13), these pumps do not include any installation fittings.
Technical
Selecting among the Walbro FR Series electric fuel pumps:
• All the FR electric pumps provide fuel until the fuel demand decreases, or flow is restricted - but they have different mechanisms for doing so.
FR pumps will cycle (pump) until they build up the pressure (head) in the outflow line - with an accompanying decrease in fuel flow - and reach their factory preset maximum pressure.
At this point, constant frequency pumps like the FRA will continue cycling - but no fuel will flow.
Variable frequency pumps, like the FRB and FRD, will slow and eventually stop cycling as the pressure builds.
If the pressure on the outflow side of the pump drops, both types of pump will start supplying fuel again.
• Choosing an FR Series pump is often less dependent on the application, and more a matter of user preference:
FRA pumps are lower cost, basic models.
They have no built-in filter, and their constant cycling means electric current draw is constant - regardless of output, they are always making noise, they typically have a shorter lifespan (higher wear), and they can wear unevenly as the stroke can be shortened when operating near their maximal pressure.
FRB and FRD pumps have a more expensive variable frequency circuit board, always use their full stroke length - so wear is evenly distributed, do not always operate at full capacity/maximal cycling — so less wear, longer life, less noise, and lower average current draw.
Additionally, the FRB models include a built-in/replaceable 70 micron mesh filter, so the user doesn't need to supply a pre-filter.
• What the FR fuel pump is designed to do:
In carbureted applications - The FRA and FRB fuel pumps self-regulate to their maximum output pressure when the carburetor bowl is full, and respond to float movement in the carburetor as required.
When the engine demands more fuel, the pump increases its flow rate.
When the engine demand drops, the pump reduces its flow rate.
In diesel applications - The FRA and FRB pumps will deliver fuel to the diesel injector pump, assuring a positive pressure at the injector pump inlet.
These pumps are designed to refill diesel filters after service or replacement.
In transfer applications, including fuel polishing, FRA and FRB pumps run continuously, as long as electrical power is supplied to the pump, and output back pressure is low.
In diesel heater and stove applications, the task-specific FRD pumps will slow their cycling rate to deliver only the fuel required by the stove fuel metering valve ("carburetor").
FRD pumps can also fill day tanks in gravity feed installations.
• Complete list of approved fuels for FR pumps: Unleaded regular gasoline, premium gasoline, gasoline-alcohol blends, diesel fuel, bio-diesel, Stoddard solvent, E85.
|
284.51 |
|
|
Walbro FRA-1-1 Electric Fuel Pump
Voltage: 12V DC
Weight: 1.63 lb
Minimum Flow Rate: 20 gph
Dry Lift: 24"
Service Life: 5,000+ hr
Fuse: 5A
Current Draw: 2.0 Amps
Inlet/Outlet: 1/8-27 NPSF
Inlet Filter Screen: 70 Micron
Magnetic Trap: None
Outlet Check Valve: No
Maximum Output Pressure: 4.0 - 7.0 psi
The FRA Series electric fuel pump operates at a constant frequency — it will continue to cycle as long as electric power is supplied.
If there is no demand for fuel, the pump will build pressure in the fuel delivery line - up to its rated maximum pressure - and continue to cycle, but with no fuel output.
As such, it is not well-suited for continuous operation/low demand applications such as heater or stove systems, since it will constantly make noise, and have a shortened service life due to high cycling.
For stove/heater and continuous duty applications, use the Walbro FRD series of pumps, which addresses these issues. See Related Products, below.
An FRA pump can be used, however, to fill a gravity-feed day tank commonly used in diesel stove and heater installations.
FRA pumps incorporate a new piston mechanism which, unlike rubber diaphragms, is not affected by modern, high-tech fuel blends.
The FRA is designed to serve as a primary pump (replacing a mechanical fuel pump) or as an auxilliary fuel pump (assisting the existing pump) for internal combustion engines.
The pump self-regulates to its pre-set pressure, pumping more or less fuel as the delivery pressure (head) varies.
FRA pumps are commonly used as replacements for failed mechanical fuel pumps on older engines, where the owner doesn't want to continue using a pump with a rubber diaphragm susceptable to degradation by modern alcohol fuel blends.
They are also commonly used in open flow, low head applications such as fuel polishing.
• Non-adjustable maximum output pressure is factory pre-set in the ranges indicated below
• Output pressure can be further regulated by screwing in, or placing in-line, an adjustable pressure regulator such as the HOL 12-804
• FRA provides low cost with good durability
• Compatible with all commercially available pump grade gasoline, gasoline-alcohol blends, diesel, and bio-diesel fuels
• Continuous duty life (diesel fuel): >5,000 hours
• Flow rates as high as 52 gph, but 30 gph is a more typical maximum
• Current draw averages less than 2 amps
• Self-priming to at least 2 feet; maximum dry run time is 4 hours
• Inlet (bottom)/Outlet (top): 1/8-27 NPSF (Dryseal American National Standard Straight Pipe Thread) — will accept NPT tapered fittings without leaking, thread sealant recommended
• No internal filter - a 70 micron, or finer, pre-filter is recommended
• USCG 16623-1 and 16623-2 approved; ignition protected
• Dichromate coating passes 96 hour salt spray test - not recommended where exposed to saltwater
• Dimensions: 5.43"H x 2.76"Dia.
• Note - a suffix number (typically -1 or -2) in part number refers to type of packaging
• Made in USA
Technical
Selecting among the Walbro FR Series electric fuel pumps:
• All the FR electric pumps provide fuel until the fuel demand decreases, or flow is restricted - but they have different mechanisms for doing so.
FR pumps will cycle (pump) until they build up the pressure (head) in the outflow line - with an accompanying decrease in fuel flow - and reach their factory preset maximum pressure.
At this point, constant frequency pumps like the FRA will continue cycling - but no fuel will flow.
Variable frequency pumps, like the FRB and FRD, will slow and eventually stop cycling as the pressure builds.
If the pressure on the outflow side of the pump drops, both types of pump will start supplying fuel again.
• Choosing an FR Series pump is often less dependent on the application, and more a matter of user preference:
— FRA pumps are lower cost, basic models.
They have no built-in filter, and their constant cycling means electric current draw is constant - regardless of output, they are always making noise, they typically have a shorter lifespan (higher wear), and they can wear unevenly as the stroke can be shortened when operating near their maximal pressure.
— FRB and FRD pumps have a more expensive variable frequency circuit board, always use their full stroke length - so wear is evenly distributed, do not always operate at full capacity/maximal cycling — so less wear, longer life, less noise, and lower average current draw.
Additionally, the FRB models include a built-in/replaceable 70 micron mesh filter, so the user doesn't need to supply a pre-filter.
• What the FR fuel pump is designed to do:
— In carbureted applications - The FRA and FRB fuel pumps self-regulate to their maximum output pressure when the carburetor bowl is full, and respond to float movement in the carburetor as required.
When the engine demands more fuel, the pump increases its flow rate.
When the engine demand drops, the pump reduces its flow rate.
— In diesel applications - The FRA and FRB pumps will deliver fuel to the diesel injector pump, assuring a positive pressure at the injector pump inlet.
These pumps are designed to refill diesel filters after service or replacement.
— In transfer applications, including fuel polishing, FRA and FRB pumps run continuously, as long as electrical power is supplied to the pump, and output back pressure is low.
— In diesel heater and stove applications, the task-specific FRD pumps will slow their cycling rate to deliver only the fuel required by the stove fuel metering valve ("carburetor").
FRD pumps can also fill day tanks in gravity feed installations.
|
331.94 |
|
|
Yamada NDP-15BSN SS Pump W/Buna Seals
NDP-15BSN AIR POWERED DOUBLE DIAPHRAGM AODD PUMPS
Yamada® NDP-15BSN series Air Powered Double Diaphragm (AODD) pumps provide a maximum flow rate of 13.5 gallons per minute. Pumps are available in aluminum, stainless steel (316), Kynar® (PVDF), groundable acetal, and polypropylene construction, with a wide variety of diaphragm materials.
Inlet (in)1/2
Outlet (in)1/2
Max Flow (gpm)13.5
Max Temp180
Max Solid (in)1/32
Valve Type (in)1/4
Air Motor MaterialRyton
Body MaterialStainless Steel
|
1320.00 |
|
|
Get 10% OFF an N76-46P Pump Body Today!
Flotec N76-46P Pump Body
This is the durable plastic pump body, that is specially designed for use with Flotec shallow well jet pumps. For use in Ponds, Fountains and watering the grass.
The Flotec, Simer and Sta-Rite pumps have interchangeable parts. If the part number is the same, it will work in any of the Flotec, Simer and Sta-Rite pumps.
For use with 1/2, 3/4, 1 HP, Model PNC, PND, PNE, Series PN.
N76-46P, Pump Body, for use with 1/2, 3/4, 1 HP, Model PNC, PND, PNE, Series PN
Get Your Coupon Code Today!
|
|
|
Cartridge Combo
Combines the line of cartdrige bilge pumps with automatic operation. Equipped with a non-clogging electronic float switch.
Specs:
Capacity 3' head (13.6V): 50l/min - 800 GPH
Capacity Straight (13.6V): 63l/min - 1000GPH
Amperage: 3.2A
Fuse Size: 5A
Connection: 3/4"
|
88.88 |
|
|
Yamada NDP-15BST 1/2" SS Teflon Pump
NDP-15BST AIR POWERED DOUBLE DIAPHRAGM AODD PUMPS
Yamada® NDP-15BST series Air Powered Double Diaphragm (AODD) pumps provide a maximum flow rate of 13.5 gallons per minute. Pumps are available in aluminum, stainless steel (316), Kynar® (PVDF), groundable acetal, and polypropylene construction, with a wide variety of diaphragm materials.
Inlet (in)1/2
Outlet (in)1/2
Max Flow (gpm)13.5
Max Temp212
Max Solid (in)1/32
Valve Type (in)1/4
Air Motor MaterialRyton
Body MaterialStainless Steel
Elastomer MaterialPTFE
|
1468.80 |
|