7611 DC BatteryLink™ Automatic Charging Relay - 120 Amp w/Auxiliary Battery Charging
Features:
120 Amp continuous rating
12/24V DC auto ranging voltage input
Senses charging on two battery banks
Side and bottom knockouts for cable connections
Clip-on cover insulates terminal connections
7/8" (22 mm) stud length to accept multiple cable terminals
Integrated LED indicates ACR status
1/4" x .032" male quick connect terminals for ground and optional features
Specifications:
Intermittent Rating: 5 min.: 210 Amps
Continuous Rating: 120 Amps
Nominal Voltage: 12/24 Volts DC
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
99.76 |
|
|
7601 DC Mini ACR Automatic Charging Relay - 65 Amp
Features:
65 Amp continuous rating manages the charging current from alternators up to 65 Amps found on most outboards and many inboard engines
Compact case design allows surface and panel mounting
Senses charging on two battery banks
Snap-on cover insulates terminal connections
LED indicates ACR status
1/4" x .032" male quick connect terminal for ground
5/8" (16 mm) stud length to accept multiple cable terminals
12V DC voltage input
Specifications:
Intermittent Rating: 5 min.: 115A
Terminal Stud Size: 1/4"-20
Relay Contact Position: Open (30 sec.): 12.75V DC
Continuous Rating: 65A
Maximum Torque: 75 in-lb (8.5 Nm)
Relay Contact Position - Open High: 16.0V DC
Amperage Operating Current: 175mA (Combine)
Relay Contact Position: Combine (30 sec.): 13.0V DC
Under Voltage Lockout: 9.5V DC
Amperage Operating Current: 15mA (Open)
Relay Contact Position: Combine (2 min.): 13.6V DC
Maximum Cable Size: 1/0 AWG
Relay Contact Position: Open (10 sec.): 12.35V DC
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
69.10 |
|
|
7621
Manual Control: No
Coil Voltage: 24V DC
Combines battery banks during charging and isolates under discharge
500 Ampere continuous rating suitable for use with large battery banks, starters, alternators, and inverter/chargers
Can be remotely combined with optional switch
Silver alloy contacts provide high reliability
3/8" copper studs, using Blue Sea Systems superior one piece stud technology, suitable for 300 Ampere continuous rating and large cable connections
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
214.24 |
|
|
7620
Manual Control: No
Coil Voltage: 12V DC
Combines battery banks during charging and isolates under discharge
500 Ampere continuous rating suitable for use with large battery banks, starters, alternators, and inverter/chargers
Includes ML-Series Remote Control Contura Switch PN 2146
Silver alloy contacts provide high reliability
3/8" copper studs, using Blue Sea Systems superior one piece stud technology, suitable for 300 Ampere continuous rating and large cable connections
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
214.24 |
|
|
7610
120 Amp SI-Series Automatic Charging Relay
Allows temporary isolation of house loads from engine circuit during engine cranking to protect sensitive electronics
Automatically combines battery banks during the charging cycle and isolates under discharge
12/24 Volt auto ranging voltage input
Waterproof rated IP67 - temporary immersion for 30 minutes
Ignition protected - safe for installation aboard gasoline powered boats
Remote LED output indicates relay state away from ACR
LED light indicates when batteries are combined
LED blinks in undervoltage lockout and starting lockout
Supports high-output alternators up to 120 Amperes
Included with the ADD A BATTERY Dual Circuit System
Automatically combines battery banks during the charging cycle and isolates under discharge
Ignition protected - safe for installation aboard gasoline-powered boats
Activates from any charging source - alternators, battery chargers, or solar panels
Hermetically sealed contacts / vaporproof
Side and bottom knockouts for power cable connections
Clip-on cover protects and insulates terminal connections
Tin-plated copper studs for maximum corrosion resistance
7/8" (22.22mm) stud length to accept multiple cable terminals
1/4" x 0.031" male quick connect terminals for ground and remote LED and starting interrupt
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
99.76 |
|
|
Programmable Automatic Charging Relay (ACR) 160A, 12V
This 160A Egis charging relay is automatic and programable. The relay eliminates dead start batteries by sharing charging on either of two batteries and isolating batteries when no charge sources are present.
Applications:
Supports multiple engines or independent charge systems by incorporating two independent start or engine isolation inputs to allow isolation of charge sources when both are active to maximize charging performance.
Protects Electrical System Cascading Faults with an optional lock-out from closing if one terminal is connected to a battery with a shorted cell.
Features:
Ultra-Low Power Draw Compared to typical ACRs (7-10 mA) vs 7610 ACR @ 1.3 mA, will not deplete batteries even after extended electrical system downtime.
Simple and robust installation - The integrated sealed plug eliminates corrosion and includes a Deutsch/Amphenol DTM connector harness
Start Assist input option to ensure maximum cranking amps are available by allowing the manual connection of batteries via a remote switch.
Bullet-proof construction - Sealed unit, stainless steel hardware, and high-temperature materials allow mounting anywhere. Integrated thermal overload shutdown protection.
Additional low-amp output can be used to report device status remotely or drive a secondary relay for charging a battery bank without a charge source (see example)
Specifications:
Continuous Current (Amps): 160
Voltage Range: 8-18 VDC
Off-State Current Draw mA: 1.3
Interrupt Current (Amps): 240
ACR Closing Voltage (VDC): 12.9-13.6
ACR Opening Voltage (VDC): 12.1-12.8
Focal Features:
Top Side Dip Switches
Accessible after mounting for programming voltage settings and determining active features. Protected by self-retained cover.
Stainless Steel Self-Locking Hardware
100% Non-ferrous corrosion-resistant materials. All attachment screws and nuts are self-locking.
Integral I/O Connector
Sealed Molex MX-150 connector eliminates the susceptibility to corrosion and vibrating loose of 1/4" quick connect terminals on competitive products.
Connection Options
Comes standard with a Deutsch DT/AT style connector harness. Provides three connection options (MX-150, DT/AT, and wire leads).
Easy Integration with RT Fuse Blocks (24 HR Circuits)
Optional EasyLink bus bars reduce the space and cost of connecting TH Series relays with RT Series Fuse Blocks.
LED Diagnostics
Provides an indication of pending relay ON/OFF, under voltage, over voltage/temp, start isolation/assist, and output on/off status.
|
104.96 |
|
|
Automatic Charging Relay Plus - 160A - 24V
This 160A Egis automatic charging relay eliminates dead-start batteries by sharing charging on either of two batteries and isolating batteries when no charge sources are present.
Applications:
Supports multiple engines or independent charge systems by incorporating two independent start or engine isolation inputs to allow isolation of charge sources when both are active to maximize charging performance
Protects Electrical System Cascading Faults with an optional lock-out from closing if one terminal is connected to a battery with a shorted cell
Features:
Ultra-low power draw compared to typical ACRs (7-10 mA) vs. the 7610 ACR @ 1.3 mA will not deplete batteries even after extended electrical system downtime.
Simple and robust installation - integrated sealed plug eliminates corrosion; includes Deutsch/Amphenol DTM connector harness
Start to assist input option to ensure maximum cranking amps are available by allowing manually connecting batteries via a remote switch
Bullet-proof construction - sealed unit, stainless steel hardware, and high-temperature materials allow mounting anywhere; Integrated thermal overload shutdown protection
Additional low-amp output can be used to report device status remotely or drive a secondary relay for charge to a battery bank without a charge source (see examples)
Specifications:
Continuous Current Amps: 160
Voltage Range (VDC): 16 – 36
Off-State Current Draw (mA): 1.3
Interrupt Current (Amps): 240
AC Closing Voltage Range (VDC): 25.8-27.2
AC Opening Voltage Range (VDC): 24.2-25.6
Focal Features:
Top Side Dip Switches
Accessible after mounting for programming voltage settings and determining active features. Protected by self-retained cover.
Stainless Steel Self-Locking Hardware
100% non-ferrous corrosion-resistant materials. All attachment screws and nuts are self-locking.
Integral I/O Connector
Sealed Molex MX-150 connector eliminates the susceptibility to corrosion and vibrating loose of 1/4" quick connect terminals on competitive products.
Connection Options
Comes standard with a Deutsch DT/AT style connector harness. Provides three connection options (MX-150, DT/AT, and wire leads).
Easy Integration with RT Fuse Blocks (24 HR Circuits)
Optional EasyLink bus bars reduce the space and cost of connecting TH Series relays with RT Series fuse blocks.
LED Diagnostics
Indicates pending relay ON/OFF, under voltage, over voltage/temp, start isolation/assist, and output on/off status.
|
105.44 |
|
|
BatteryLink® Charger - 10Amp - 2-Bank
Charge two batteries at or away from the dock with a 10A multistage battery charger and integrated 65A Automatic Charging Relay (ACR)
AC charging at the dock: Use AC shore power to charge two isolated battery banks with the 3 Stage 10 Amp battery charger
DC charging away from the dock: Share the DC power from the alternator with both the Start and the Auxiliary battery through the integrated 65A ACR
Battery Temperature Compensation prolongs battery life
Start isolation protects sensitive electronics from voltage sags and spikes
Includes LED remote indicator for charge status at the helm
Snap-on insulating cover
One-piece stainless flange nuts ensure safe and secure connections
Specifications
Total Output Current: 10A
Nominal Voltage: 12V DC
Number of Outputs: 1 negative / 2 positive
Terminal Stud Torque: 60 in-lb (6.78 Nm)
Continuous Rating:65A
Intermittent Rating:115A
Universal AC Input Voltage: 90-265V AC
AC Input Frequency: 50/60Hz
Typical Float Voltage:13.5V DC
Battery Types: AGM / Flooded / TPPL - Do not mix battery types
Cable Size to Meet Ratings:10 AWG Negative Cable / 6 AWG Positive Cable
Maximum Battery CCA: 850CCA
Maximum Cable Size: 1/0 AWG (50mm)
Operating Current: 10mA (No AC Power, ACR Open) / 60mA (No AC Power, ACR Closed)
Recommended Battery Bank Sizes: 60Ah Minimum
Terminal Stud Size:1/4"-20 (accepts M6 ring terminal)
Warranty: 5 Year
Combine 30 sec: 13.5V
Combine 2 Min: 13.0V
Open 10 sec: 12.35V
Open 30 sec: 12.75V
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
204.91 |
|
|
Mini Add-A-Battery Plus Kit - 10A
A complete small boat battery management system. Charge two batteries at or away from the dock.
For alternators up to 65A
Includes a Dual Circuit Plus™ Battery Switch 6011 a 3 Stage, 10 Amp charger with an integrated 65A Automatic Charging Relay, and a LED charger remote mSeries Dual Circuit Plus™ Battery Switch
Switches two battery banks simultaneously while maintaining battery bank isolation
Can combine two battery banks in the event of a low start battery
IP66 - protected against powerful water jets
BatteryLink® Charger
Integrated ACR provides DC charging from engine alternator
AC plug-in while at the dock
Battery temperature compensation prolongs battery life
Includes a remote LED indicator
Start isolation protects sensitive electronics from voltage sags and spikes
IP67 - protected against immersion up to 1M for 30 minutes
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
245.88 |
|
|
7620100 ML ACR Charging Relay 12V 500A with Deutsch Connector
500 Amp magnetic latching (bi-stable) relay automatically combines batteries during charging and isolates batteries when discharging and when starting engine.
Features:
Automatically manages the charging of two large battery banks
Allows paralleling of battery banks for emergency starting
500 Ampere continuous rating to support high-output alternators
Magnetic Latch (ML)—ACR draws very low current (<40mA to monitor terminal voltage) in the "ON" or "OFF" states, and draws moderate current for very short time when changing state
Dual sensing—senses charge on both battery banks
Start Isolation (SI)—can be configured for temporary isolation of House loads from Engine circuit during engine cranking to protect sensitive electronics
Engine Isolation (EI)—can be configured for isolation of two engines while both are running to protect engine electronics and maximize alternator output
Senses charging on two battery banks
LED output to remotely indicate when batteries are combined, isolated, in voltage lockout, or in Start or Engine isolation
3/8"-16 tin-plated copper studs for maximum conductivity and corrosion resistance
7/8" (22mm) stud length accepts multiple cable terminals
Silver alloy contacts provide high reliability for switching live loads
Label recesses for circuit identification
Specifications:
Control Circuit Connection: Deutsch DTM
Nominal Voltage: 12VDC
Manual Control: No
Engine Isolation: Yes
Mounting: #10
Start Assist: Yes
Start Isolation: Yes
Amperage Operating Current When Changing State: <7.0A
Terminal Stud Torque: 140 in-lb (15.82 Nm)
Continuous Rating: 500A
Intermittent Rating: 700A (5 min)
Cranking Rating 30 Seconds: 1450A DC
Cable Size to Meet Ratings: 2x (4/0)
Live Current Switching: 300A@12VDC
Master Control Switch Capability: No
Switching Cycles: 100,000
Terminal Ring Diameter Clearance: 1.18" (29.97 mm)
Terminal Stud Length: 1.50" (38.1 mm)
Terminal Stud Size: 3/8" - 16 (M10)
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
222.44 |
|
|
7621100 ML ACR Charging Relay 24V 500A with Deutsch Connector
500 Amp magnetic latching (bi-stable) relay automatically combines batteries during charging and isolates batteries when discharging and when starting engine.
Features:
Automatically manages the charging of two large battery banks
Allows paralleling of battery banks for emergency starting
500 Ampere continuous rating to support high-output alternators
Magnetic Latch (ML)—ACR draws very low current (<40mA to monitor terminal voltage) in the "ON" or "OFF" states, and draws moderate current for very short time when changing state
Dual sensing—senses charge on both battery banks
Start Isolation (SI)—can be configured for temporary isolation of House loads from Engine circuit during engine cranking to protect sensitive electronics
Engine Isolation (EI)—can be configured for isolation of two engines while both are running to protect engine electronics and maximize alternator output
Senses charging on two battery banks
LED output to remotely indicate when batteries are combined, isolated, in voltage lockout, or in Start or Engine isolation
3/8"-16 tin-plated copper studs for maximum conductivity and corrosion resistance
7/8" (22mm) stud length accepts multiple cable terminals
Silver alloy contacts provide high reliability for switching live loads
Label recesses for circuit identification
Specifications:
Control Circuit Connection: Deutsch DTM
Nominal Voltage: 24VDC
Manual Control: No
Engine Isolation: Yes
Mounting: #10
Start Assist: Yes
Start Isolation: Yes
Amperage Operating Current When Changing State: <7.0A
Terminal Stud Torque: 140 in-lb (15.82 Nm)
Continuous Rating: 500A
Intermittent Rating: 700A (5 min)
Cranking Rating 30 Seconds: 1450A DC
Cable Size to Meet Ratings: 2x (4/0)
Live Current Switching: 300A@12VDC
Master Control Switch Capability: No
Switching Cycles: 100,000
Terminal Ring Diameter Clearance: 1.18" (29.97 mm)
Terminal Stud Length: 1.50" (38.1 mm)
Terminal Stud Size: 3/8" - 16 (M10)
|
222.44 |
|
|
7622100 ML ACR Charging Relay 12V 500A with Manual Control & Deutsch Connector
500 Amp magnetic latching (bi-stable) relay automatically combines batteries during charging and isolates batteries when discharging and when starting engine.
Features:
Manual control switch provides an added level of safety allowing control with or without power, and offering LOCK OFF capability for servicing
Automatically manages the charging of two large battery banks
Allows paralleling of battery banks for emergency starting
500 Ampere continuous rating to support high-output alternators
Magnetic Latch (ML)—ACR draws very low current (<40mA to monitor terminal voltage) in the "ON" or "OFF" states, and draws moderate current for very short time when changing state
Dual sensing—senses charge on both battery banks
Start Isolation (SI)—can be configured for temporary isolation of House loads from Engine circuit during engine cranking to protect sensitive electronics
Engine Isolation (EI)—can be configured for isolation of two engines while both are running to protect engine electronics and maximize alternator output
Senses charging on two battery banks
LED output to remotely indicate when batteries are combined, isolated, in voltage lockout, or in Start or Engine isolation
3/8"-16 tin-plated copper studs for maximum conductivity and corrosion resistance
7/8" (22mm) stud length accepts multiple cable terminals
Silver alloy contacts provide high reliability for switching live loads
Label recesses for circuit identification
Specifications:
Control Circuit Connection: Deutsch DTM
Nominal Voltage: 12VDC
Manual Control: Yes
Engine Isolation: Yes
Mounting: #10
Start Assist: Yes
Start Isolation: Yes
Amperage Operating Current: 13mA
Amperage Operating Current When Changing State: <7.0A
Terminal Stud Torque: 140 in-lb (15.82 Nm)
Continuous Rating: 500A
Intermittent Rating: 700A (5 min)
Cranking Rating 30 Seconds: 1450A DC
Cable Size to Meet Ratings: 2x (4/0)
Live Current Switching: 300A@12VDC
Switching Cycles: 100,000
Terminal Ring Diameter Clearance: 1.18" (29.97 mm)
Terminal Stud Length: 0.875" (22.23 mm)
Terminal Stud Size: 3/8" - 16 (M10)
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
233.82 |
|
|
7623100 ML ACR Charging Relay 24V 500A with Manual Control & Deutsch Connector
500 Amp magnetic latching (bi-stable) relay automatically combines batteries during charging and isolates batteries when discharging and when starting engine.
Features:
Manual control switch provides an added level of safety allowing control with or without power, and offering LOCK OFF capability for servicing
Automatically manages the charging of two large battery banks
Allows paralleling of battery banks for emergency starting
500 Ampere continuous rating to support high-output alternators
Magnetic Latch (ML)—ACR draws very low current (<40mA to monitor terminal voltage) in the "ON" or "OFF" states, and draws moderate current for very short time when changing state
Dual sensing—senses charge on both battery banks
Start Isolation (SI)—can be configured for temporary isolation of House loads from Engine circuit during engine cranking to protect sensitive electronics
Engine Isolation (EI)—can be configured for isolation of two engines while both are running to protect engine electronics and maximize alternator output
Senses charging on two battery banks
LED output to remotely indicate when batteries are combined, isolated, in voltage lockout, or in Start or Engine isolation
3/8"-16 tin-plated copper studs for maximum conductivity and corrosion resistance
7/8" (22mm) stud length accepts multiple cable terminals
Silver alloy contacts provide high reliability for switching live loads
Label recesses for circuit identification
Specifications:
Control Circuit Connection: Deutsch DTM
Nominal Voltage: 24VDC
Manual Control: Yes
Engine Isolation: Yes
Mounting: #10
Start Assist: Yes
Start Isolation: Yes
Amperage Operating Current: 13mA
Amperage Operating Current When Changing State: <7.0A
Terminal Stud Torque: 140 in-lb (15.82 Nm)
Continuous Rating: 500A
Intermittent Rating: 700A (5 min)
Cranking Rating 30 Seconds: 1450A DC
Cable Size to Meet Ratings: 2x (4/0)
Live Current Switching: 300A@12VDC
Switching Cycles: 100,000
Terminal Ring Diameter Clearance: 1.18" (29.97 mm)
Terminal Stud Length: 0.875" (22.23 mm)
Terminal Stud Size: 3/8" - 16 (M10)
|
233.82 |
|
|
160A Automatic Charge Isolator - 12V or 24V
The ACR-160 combines battery banks for charging and isolates them when charging has stopped. It provides priority for charging only the starter battery first and protects from excessive discharging of the starter battery.
The Automatic Charge Isolator is also referred to as a battery separator, battery isolator or an automatic charging relay.
Features:
Microprocessor controlled, dual sensing
Easy to install - does not require charging the existing circuit of the alternator
Potted, waterproof, sealed unit
Low standby current
Automatic detection of 12 or 24 VDC systems
160 Amp continuous rated, 480 Amp peak (250 msec)
Monitoring of relay activation by external LED
Over voltage protection
Specifications:
Input: 12/24 VDC
Output: 12/24 VDC
Amps: 160
Warranty: 2 Year Limited
Applications:
Marine
Automotive
Recreational
WARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
127.37 |
|
|
Add-A-Battery
7650
The 7650 Add-a-Battery simplifies switching and automates charging for a complete two battery bank management solution.
A complete two battery bank management solution
Dual Circuit Plus™ Battery Switch isolates engine and house circuits, and combines battery banks for emergency starting
The 120 Amp SI ACR automatic charging relay combines for charging
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
149.92 |
|