Prop installation hardware, sold 1 piece per package.
|
7.69 |
|
|
C-Series ELCI Circuit Breaker - Double Pole 240V AC 50A
Features:
Trips on short circuits, overloads, or leakage to ground
Front panel mount—installed in a power distribution panel
Specifications:
Amperage: 50A
Actuator Style: Flat Rocker
Poles: 2
Ignition Protected: Yes
Maximum Voltage: 120V AC per pole & 240V AC per pole
Circuit Breaker Type: Magnetic Hydraulic (trip free)
Interrupt Capacity: 5000A
Minimum Operating Temperature: -35° C
Maximum Operating Temperature: 66° C
Leakage Trip Amps: 30mA
Mounting Screw: #6-32 Stainless Steel
Mounting Screw Torque: 6 in-lb (0.68 Nm)
Switching Cycles: 10000
Weight: 1.20 lb. (0.54 kg)
WARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
553.70 |
|
|
Sherwood 11068 MAJOR KIT FOR RP-B-C, E-35
|
289.09 |
|
|
C-Series Flat Rocker Circuit Breaker - Single Pole - 5A
Features:
Rocker actuator is flush in the "ON" position, eliminating the risk of accidential switching
Color actuator indicates "OFF" position
Provides overcurrent protection for inverters, bow thrusters, and windlasses
Combines switching and circuit protection into a single device
"Trip Free" - cannot be held closed after trip
Ignition protectedsafe for installation aboard gasoline powered boats
Specifications:
Amperage: 5A AC / 5A DC
Actuator Style: Flat Rocker
Poles: 1
Maximum Voltage: 240V AC / 48V DC
Circuit Breaker Type: Magnetic Hydraulic - trip free
Terminal Stud Torque: 35 in-lb (3.95 Nm)
Interrupt Capacity: 3000A @ 120V AC / 3500A @ 240V AC / 5000A @ 32V DC
Minimum Operating Temperature: -40° C
Maximum Operating Temperature: 85° C
Mounting Screw: #6-32 Stainless Steel
Mounting Screw Torque: 6 in-lb (0.68 Nm)
Switching Cycles: 10000
Terminal Stud: 1/4-20 Tin-Plated Brass
Weight: 0.38lb (0.17 kg)
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
31.02 |
|
|
C-Series Flat Rocker Circuit Breaker - Single Pole - 10A
Features:
Rocker actuator is flush in the "ON" position, eliminating the risk of accidential switching
Color actuator indicates "OFF" position
Provides overcurrent protection for inverters, bow thrusters, and windlasses
Combines switching and circuit protection into a single device
"Trip Free" - cannot be held closed after trip
Ignition protectedsafe for installation aboard gasoline powered boats
Specifications:
Amperage: 10A AC / 10A DC
Actuator Style: Flat Rocker
Poles: 1
Maximum Voltage: 240V AC / 48V DC
Circuit Breaker Type: Magnetic Hydraulic - trip free
Terminal Stud Torque: 35 in-lb (3.95 Nm)
Interrupt Capacity: 3000A @ 120V AC / 3500A @ 240V AC / 5000A @ 32V DC
Minimum Operating Temperature: -40° C
Maximum Operating Temperature: 85° C
Mounting Screw: #6-32 Stainless Steel
Mounting Screw Torque: 6 in-lb (0.68 Nm)
Switching Cycles: 10000
Terminal Stud: 1/4-20 Tin-Plated Brass
Weight: 0.38lb (0.17 kg)
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
31.02 |
|
|
C-Series Flat Rocker Circuit Breaker - Single Pole - 15A
Features:
Rocker actuator is flush in the "ON" position, eliminating the risk of accidential switching
Color actuator indicates "OFF" position
Provides overcurrent protection for inverters, bow thrusters, and windlasses
Combines switching and circuit protection into a single device
"Trip Free" - cannot be held closed after trip
Ignition protectedsafe for installation aboard gasoline powered boats
Specifications:
Amperage: 15A AC / 15A DC
Actuator Style: Flat Rocker
Poles: 1
Maximum Voltage: 240V AC / 48V DC
Circuit Breaker Type: Magnetic Hydraulic - trip free
Terminal Stud Torque: 35 in-lb (3.95 Nm)
Interrupt Capacity: 3000A @ 120V AC / 3500A @ 240V AC / 5000A @ 32V DC
Minimum Operating Temperature: -40° C
Maximum Operating Temperature: 85° C
Mounting Screw: #6-32 Stainless Steel
Mounting Screw Torque: 6 in-lb (0.68 Nm)
Switching Cycles: 10000
Terminal Stud: 1/4-20 Tin-Plated Brass
Weight: 0.38lb (0.17 kg)
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
31.02 |
|
|
C-Series Flat Rocker Circuit Breaker - Single Pole - 20A
Features:
Rocker actuator is flush in the "ON" position, eliminating the risk of accidential switching
Color actuator indicates "OFF" position
Provides overcurrent protection for inverters, bow thrusters, and windlasses
Combines switching and circuit protection into a single device
"Trip Free" - cannot be held closed after trip
Ignition protectedsafe for installation aboard gasoline powered boats
Specifications:
Amperage: 20A AC / 20A DC
Actuator Style: Flat Rocker
Poles: 1
Maximum Voltage: 240V AC / 48V DC
Circuit Breaker Type: Magnetic Hydraulic - trip free
Terminal Stud Torque: 35 in-lb (3.95 Nm)
Interrupt Capacity: 3000A @ 120V AC / 3500A @ 240V AC / 5000A @ 32V DC
Minimum Operating Temperature: -40° C
Maximum Operating Temperature: 85° C
Mounting Screw: #6-32 Stainless Steel
Mounting Screw Torque: 6 in-lb (0.68 Nm)
Switching Cycles: 10000
Terminal Stud: 1/4-20 Tin-Plated Brass
Weight: 0.38lb (0.17 kg)
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
31.02 |
|
|
C-Series Flat Rocker Circuit Breaker - Single Pole - 30A
Features:
Rocker actuator is flush in the "ON" position, eliminating the risk of accidential switching
Color actuator indicates "OFF" position
Provides overcurrent protection for inverters, bow thrusters, and windlasses
Combines switching and circuit protection into a single device
"Trip Free" - cannot be held closed after trip
Ignition protectedsafe for installation aboard gasoline powered boats
Specifications:
Amperage: 30A AC / 30A DC
Actuator Style: Flat Rocker
Poles: 1
Maximum Voltage: 240V AC / 48V DC
Circuit Breaker Type: Magnetic Hydraulic - trip free
Terminal Stud Torque: 35 in-lb (3.95 Nm)
Interrupt Capacity: 3000A @ 120V AC / 3500A @ 240V AC / 5000A @ 32V DC
Minimum Operating Temperature: -40° C
Maximum Operating Temperature: 85° C
Mounting Screw: #6-32 Stainless Steel
Mounting Screw Torque: 6 in-lb (0.68 Nm)
Switching Cycles: 10000
Terminal Stud: 1/4-20 Tin-Plated Brass
Weight: 0.38lb (0.17 kg)
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
31.02 |
|
|
C-Series Flat Rocker Circuit Breaker - Single Pole - 50A
Features:
Rocker actuator is flush in the "ON" position, eliminating the risk of accidential switching
Color actuator indicates "OFF" position
Provides overcurrent protection for inverters, bow thrusters, and windlasses
Combines switching and circuit protection into a single device
"Trip Free" - cannot be held closed after trip
Ignition protectedsafe for installation aboard gasoline powered boats
Specifications:
Amperage: 50A AC / 50A DC
Actuator Style: Flat Rocker
Poles: 1
Maximum Voltage: 240V AC / 48V DC
Circuit Breaker Type: Magnetic Hydraulic - trip free
Terminal Stud Torque: 35 in-lb (3.95 Nm)
Interrupt Capacity: 3000A @ 120V AC / 3500A @ 240V AC / 5000A @ 32V DC
Minimum Operating Temperature: -40° C
Maximum Operating Temperature: 85° C
Mounting Screw: #6-32 Stainless Steel
Mounting Screw Torque: 6 in-lb (0.68 Nm)
Switching Cycles: 10000
Terminal Stud: 1/4-20 Tin-Plated Brass
Weight: 0.38lb (0.17 kg)
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
31.02 |
|
|
C-Series Flat Rocker Circuit Breaker - Single Pole - 60A
Features:
Rocker actuator is flush in the "ON" position, eliminating the risk of accidential switching
Color actuator indicates "OFF" position
Provides overcurrent protection for inverters, bow thrusters, and windlasses
Combines switching and circuit protection into a single device
"Trip Free" - cannot be held closed after trip
Ignition protectedsafe for installation aboard gasoline powered boats
Specifications:
Amperage: 60A AC / 60A DC
Actuator Style: Flat Rocker
Poles: 1
Maximum Voltage: 240V AC / 48V DC
Circuit Breaker Type: Magnetic Hydraulic - trip free
Terminal Stud Torque: 35 in-lb (3.95 Nm)
Interrupt Capacity: 3000A @ 120V AC / 3500A @ 240V AC / 5000A @ 32V DC
Minimum Operating Temperature: -40° C
Maximum Operating Temperature: 85° C
Mounting Screw: #6-32 Stainless Steel
Mounting Screw Torque: 6 in-lb (0.68 Nm)
Switching Cycles: 10000
Terminal Stud: 1/4-20 Tin-Plated Brass
Weight: 0.38lb (0.17 kg)
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
31.02 |
|
|
C-Series Flat Rocker Circuit Breaker - Single Pole - 80A
Features:
Rocker actuator is flush in the "ON" position, eliminating the risk of accidential switching
Color actuator indicates "OFF" position
Provides overcurrent protection for inverters, bow thrusters, and windlasses
Combines switching and circuit protection into a single device
"Trip Free" - cannot be held closed after trip
Ignition protectedsafe for installation aboard gasoline powered boats
Specifications:
Amperage: 80A AC / 80A DC
Actuator Style: Flat Rocker
Poles: 1
Maximum Voltage: 240V AC / 48V DC
Circuit Breaker Type: Magnetic Hydraulic - trip free
Terminal Stud Torque: 35 in-lb (3.95 Nm)
Interrupt Capacity: 3000A @ 120V AC / 3500A @ 240V AC / 5000A @ 32V DC
Minimum Operating Temperature: -40° C
Maximum Operating Temperature: 85° C
Mounting Screw: #6-32 Stainless Steel
Mounting Screw Torque: 6 in-lb (0.68 Nm)
Switching Cycles: 10000
Terminal Stud: 1/4-20 Tin-Plated Brass
Weight: 0.38lb (0.17 kg)
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
31.02 |
|
|
C-Series Flat Rocker Circuit Breaker - Single Pole - 100A
Features:
Rocker actuator is flush in the "ON" position, eliminating the risk of accidential switching
Color actuator indicates "OFF" position
Provides overcurrent protection for inverters, bow thrusters, and windlasses
Combines switching and circuit protection into a single device
"Trip Free" - cannot be held closed after trip
Ignition protectedsafe for installation aboard gasoline powered boats
Specifications:
Amperage: 100A AC / 100A DC
Actuator Style: Flat Rocker
Poles: 1
Maximum Voltage: 240V AC / 48V DC
Circuit Breaker Type: Magnetic Hydraulic - trip free
Terminal Stud Torque: 35 in-lb (3.95 Nm)
Interrupt Capacity: 3000A @ 120V AC / 3500A @ 240V AC / 5000A @ 32V DC
Minimum Operating Temperature: -40° C
Maximum Operating Temperature: 85° C
Mounting Screw: #6-32 Stainless Steel
Mounting Screw Torque: 6 in-lb (0.68 Nm)
Switching Cycles: 10000
Terminal Stud: 1/4-20 Tin-Plated Brass
Weight: 0.38lb (0.17 kg)
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
31.02 |
|
|
C-Series Solar Charge Controller - 60 Amps
PV charge, diversion and load controller
The C35 and C60 are field configurable for 12 V and 24 V operation. The C40 may be configured for 12 V, 24 V, or 48 V operation. C35, C40 and C60 charge controllers can be used as a charge, diversion, or load controller and come with a standard multi-color charge status LED face plate.
A Controller for Virtually any DC Charging Source. The C60 is a fully solid state, microprocessor-driven controller that is UL and cUL listed. C Series controllers may be configured for PV battery charging, or DC load control or DC diversion operation. Whatever the charging source, a C Series controller is sure to meet your DC controller needs.
Silent Microprocessor Control-All C Series controllers have a powerful microprocessor at their core which increases system performance and maximizes battery life. They are fully solid state and operate silently.
Features:
Improve battery life with pulse width modulated (PWM) multi-stage temperature compensated charging
Two-year standard warranty
PV charge, diversion, load controller
Available remote display with cumulative AMP hours
Electronic protection against short-circuit, overload, and over-temperature conditions
Tolerance to hostile environments with conformal-coated boards and powder-coated enclosure
Field adjustable voltage and battery set point
Automatically disconnects from the battery at night
Compatible with negative ground and ungrounded systems
WARNING: This product can expose you to chemicals including Diisononyl Phthalate (DINP) which is known to the State of California to cause cancer, and Di-isodecyl Phthalate (DIDP) which is known to the State of California to cause reproductive harm. For more information go to P65Warnings.ca.gov.
|
162.91 |
|
|
C-Series ELCI Main Circuit Breaker - Double Pole 120V AC 50A
Features:
Provides over current and leakage protection per ABYC E-11 for whole boat shore power protection
Meets UL 1500 external ignition protection requirements
Trips on short circuit, overload, or leakage to ground
Front panel mount—installed in a power distribution panel
Specifications:
Amperage: 50A
Actuator Style: Flat Rocker
Poles: 2
Ignition Protected: Yes
Max Voltage: 120VAC per pole
Circuit Breaker Type: Magnetic Hydraulic - trip free
Interrupt Capacity: 5000A
Minimum Operating Temperature: -35 degrees C
Max Operating Temperature: 66 degrees C
Leakage Trip Amps: 30mA
|
453.26 |
|
|
C-Series ELCI Main Circuit Breaker - 120/240V AC 50A
Features:
Provides over current and leakage protection per ABYC E-11 for whole boat shore power protection
Meets UL 1500 external ignition protection requirements
Trips on short circuit, overload, or leakage to ground
Front panel mount—installed in a power distribution panel
Specifications:
Amperage: 50A
Actuator Style: Flat Rocker
Poles: 3
Ignition Protected: Yes
Max Voltage: 120VAC per pole/240VAC per pole
Circuit Breaker Type: Magnetic Hydraulic - trip free
Interrupt Capacity: 5000A
Minimum Operating Temperature: -35 degrees C
Max Operating Temperature: 66 degrees C
Leakage Trip Amps: 30mA
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
506.70 |
|