Panel Plug Kit
Includes circuit breaker mounting screws, C-Series panel plug, LED plug and blank label
Designed for C-Series Circuit Breakers
Heavy 1/8" aluminum 5052 Alloy
Two-part polyurethane slate gray finish
Accepts standard Blue Sea Systems' backlight labels
Accepts standard Blue Sea Systems' "ON" indication LEDs
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
3.77 |
|
|
C-Series Triple-Pole Flat Rocker Circuit Breaker
Features:
One 50 Ampere triple-pole C-Series circuit breaker installed
Backlit circuit label positions
Flexible 360 Panel System configuration provides spare rocker apertures which may be used for single-pole 120 Volt AC or double-pole 240 Volt AC Branch circuits
Specifications:
Positions: 1
Nominal Voltage: 120/240V AC
Backlit Label*: Green LED
Height: 4.75" (120.65mm)
Width: 4.88" (123.95mm)
Depth: 3.00" (76.2mm)
Weight: 1.80lb (0.82kg)
Includes:
(1) - 7565 - C-Series Flat Rocker Circuit Breaker - Triple Pole 50A AC (Main)
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
262.31 |
|
|
C-Series Toggle Single Pole
PN: 7244
Poles: 1
Color: White
Amperage: 50A
Features:
Provides overcurrent protection for inverters, bow thrusters, and windlasses
Combines switching and circuit protection into a single device
"Trip Free" - cannot be held closed after trip
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
36.38 |
|
|
C-Series Toggle Single Pole
PN: 7246
Poles: 1
Color: White
Amperage: 60A
Features:
Provides overcurrent protection for inverters, bow thrusters, and windlasses
Combines switching and circuit protection into a single device
"Trip Free" - cannot be held closed after trip
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
36.38 |
|
|
C-Series Toggle Single Pole
PN: 7248
Poles: 1
Color: White
Amperage: 80A
Features:
Provides overcurrent protection for inverters, bow thrusters, and windlasses
Combines switching and circuit protection into a single device
"Trip Free" - cannot be held closed after trip
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
36.38 |
|
|
C-Series Toggle Single Pole
PN: 7250
Poles: 1
Color: White
Amperage: 100A
Features:
Provides overcurrent protection for inverters, bow thrusters, and windlasses
Combines switching and circuit protection into a single device
"Trip Free" - cannot be held closed after trip
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
36.38 |
|
|
C-Series Toggle
PN: 7251
Poles: 2
Color: White
Amperage: 50A
Features:
5,000 Ampere interrupt capacity to meet ABYC requirements for 120/240 Volt 50 Ampere main protection
Double pole used as 120 volt AC main circuit breaker to switch hot to neutral
Triple pole used as 240 volt AC main circuit breaker to switch lines (hot) and neutral
Double and triple pole circuit breakers will trip all poles will trip if any one pole trips
"Trip Free" design cannot be held ON during fault current condition
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
87.55 |
|
|
C-Series Toggle
PN: 7254
Poles: 2
Color: White
Amperage: 60A
Features:
5,000 Ampere interrupt capacity to meet ABYC requirements for 120/240 Volt 50 Ampere main protection
Double pole used as 120 volt AC main circuit breaker to switch hot to neutral
Triple pole used as 240 volt AC main circuit breaker to switch lines (hot) and neutral
Double and triple pole circuit breakers will trip all poles will trip if any one pole trips
"Trip Free" design cannot be held ON during fault current condition
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
87.55 |
|
|
C-Series Toggle
PN: 7256
Poles: 2
Color: White
Amperage: 80A
Features:
5,000 Ampere interrupt capacity to meet ABYC requirements for 120/240 Volt 50 Ampere main protection
Double pole used as 120 volt AC main circuit breaker to switch hot to neutral
Triple pole used as 240 volt AC main circuit breaker to switch lines (hot) and neutral
Double and triple pole circuit breakers will trip all poles will trip if any one pole trips
"Trip Free" design cannot be held ON during fault current condition
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
87.55 |
|
|
C-Series Toggle
PN: 7258
Poles: 2
Color: White
Amperage: 100A
Features:
5,000 Ampere interrupt capacity to meet ABYC requirements for 120/240 Volt 50 Ampere main protection
Double pole used as 120 volt AC main circuit breaker to switch hot to neutral
Triple pole used as 240 volt AC main circuit breaker to switch lines (hot) and neutral
Double and triple pole circuit breakers will trip all poles will trip if any one pole trips
"Trip Free" design cannot be held ON during fault current condition
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
87.55 |
|
|
C-Series Toggle
PN: 7287
Poles: 3
Color: White
Amperage: 50A
Features:
5,000 Ampere interrupt capacity to meet ABYC requirements for 120/240 Volt 50 Ampere main protection
Double pole used as 120 volt AC main circuit breaker to switch hot to neutral
Triple pole used as 240 volt AC main circuit breaker to switch lines (hot) and neutral
Double and triple pole circuit breakers will trip all poles will trip if any one pole trips
"Trip Free" design cannot be held "ON" during fault current condition
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
112.92 |
|
|
C-Series Toggle
PN: 7288
Poles: 3
Color: White
Amperage: 60A
Features:
5,000 Ampere interrupt capacity to meet ABYC requirements for 120/240 Volt 50 Ampere main protection
Double pole used as 120 volt AC main circuit breaker to switch hot to neutral
Triple pole used as 240 volt AC main circuit breaker to switch lines (hot) and neutral
Double and triple pole circuit breakers will trip all poles will trip if any one pole trips
"Trip Free" design cannot be held "ON" during fault current condition
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
112.92 |
|
|
C-Series Toggle
PN: 7289
Poles: 3
Color: White
Amperage: 80A
Features:
5,000 Ampere interrupt capacity to meet ABYC requirements for 120/240 Volt 50 Ampere main protection
Double pole used as 120 volt AC main circuit breaker to switch hot to neutral
Triple pole used as 240 volt AC main circuit breaker to switch lines (hot) and neutral
Double and triple pole circuit breakers will trip all poles will trip if any one pole trips
"Trip Free" design cannot be held "ON" during fault current condition
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
112.92 |
|
|
C-Series Toggle
PN: 7290
Poles: 3
Color: White
Amperage: 100A
Features:
5,000 Ampere interrupt capacity to meet ABYC requirements for 120/240 Volt 50 Ampere main protection
Double pole used as 120 volt AC main circuit breaker to switch hot to neutral
Triple pole used as 240 volt AC main circuit breaker to switch lines (hot) and neutral
Double and triple pole circuit breakers will trip all poles will trip if any one pole trips
"Trip Free" design cannot be held "ON" during fault current condition
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
112.92 |
|
|
C-Series Toggle Single Pole
PN: 7350
Poles: 1
Color: White
Amperage: 5A
Features:
Provides overcurrent protection for inverters, bow thrusters, and windlasses
Combines switching and circuit protection into a single device
"Trip Free" - cannot be held closed after trip
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
36.38 |
|