Tuthill 50218500 Housing Bushing for HD Series Rotary Lobe Pumps
The Tuthill 50218500 is a genuine housing bushing for Tuthill HD Series rotary lobe process pumps. The bushings support the shafts where they pass through the impeller housing, and they are the parts that decide whether the impellers stay concentric in their bores as the pump takes load. When a lobe pump has begun to rub, worn bushings are the first thing to rule in or out.
Tuthill fits DU bushings in the ductile iron pumps and carbon bushings in the stainless pumps, with high temperature carbon available where the duty runs to the 525 degree F band. Two are called for per pump. A bushing that has worn oval lets the impeller drop against the housing, so it is checked whenever the pump is opened. Fit them square and check that the shafts turn freely afterwards. A bushing driven in at an angle will bind and heat up within the first hour of running.
Key Features
- Genuine Tuthill housing bushing
- Direct replacement for HD Series rotary lobe pumps
- Parts list calls for two per pump
- Published in DU and carbon materials to suit the pump build
- High temperature carbon versions available for hot duty
- Supports the shafts where they pass through the impeller housing
Applications
- Viscous and abrasive slurry transfer
- Corrosive acid and chemical process duty
- Fluids carrying suspended solids that must not be sheared
- Heavy process oils, resins and adhesives
- Scheduled overhaul of Tuthill rotary lobe process pumps
- Critical spares holding for continuous process plant
Specifications
- Brand: Tuthill
- Manufacturer Part Number: 50218500
- Part Type: Housing Bushing
- Fits: Tuthill HD Series rotary lobe process pumps
- Quantity Required: 2 per pump
- Condition: New
Frequently Asked Questions
Q: What wears a bushing fastest?
Abrasive solids in the fluid, running dry, and any misalignment that loads the shaft off axis.
Q: Do the clearances need checking afterwards?
Yes. Anything that changes shaft position changes impeller clearance, and that has to be reset.
Q: Can a worn bushing be machined oversize?
Fitting the correct replacement is the published repair. Reworking a bushing bore changes the clearance the pump was designed around.
Q: How do I know a bushing has worn?
Check for play at the shaft with the pump open, and look for an oval wear pattern in the bore. Rubbing marks on the impeller or the housing point the same way.