Pulsafeeder L3201HC1-FPP Discharge Valve Assembly
The Pulsafeeder L3201HC1-FPP is a genuine Pulsatron discharge valve assembly for pumps with the PHC1 wet end: a GFPPL body with CSPE seat and O-ring and ceramic check ball, and a 3/8 in OD tubing connection. It threads into the top of the pump head, where it opens on the discharge stroke to send chemical out to the injection point and closes on the suction stroke so the discharge line cannot drain back into the head.
A check valve that is not seating cleanly is the most common reason a solenoid metering pump loses output or will not hold prime. Crystals from the chemical, grit past a damaged strainer, or a swollen O-ring are the usual causes, and the fix is a new cartridge rather than cleaning an old one. The PHC1 code is the second half of the pump model number, so check the label before ordering. The same cartridge is part of the K2PHC1, K3PHC1 and K4PHC1.
Key Features
- Genuine Pulsatron discharge valve assembly
- For PHC1 wet end pumps
- GFPPL valve body
- CSPE seat and O-ring
- Ceramic check ball
- 3/8 in OD tubing connection
- Complete cartridge, ready to install
Applications
- Pulsatron pumps with the PHC1 wet end code
- Restoring lost prime or output
- Replacing a crystallized or leaking valve
- Water treatment and disinfection systems
- Marine and industrial chemical dosing
- Spares kit for critical feed pumps
Specifications
- Brand: Pulsafeeder Pulsatron
- Manufacturer Part Number: L3201HC1-FPP
- Part Type: Discharge valve assembly
- Wet End Code: PHC1
- Body Material: GFPPL
- Seat and O-Ring: CSPE
- Ball: Ceramic
- Connection: 3/8 in OD tubing
- Quantity Needed: One per pump
- Condition: New
Frequently Asked Questions
Q: Why is my pump still losing prime with new valves?
Look for an air leak at the suction tubing connection, a blocked foot valve strainer, or gas building in the head. Bleeding the head after startup clears trapped air.
Q: Which way up does it go?
The flow arrow on the cartridge must point in the direction of flow, which is upward through the head. A cartridge fitted upside down will stop the pump from priming at all.
Q: How tight should it be?
Hand tight plus a small amount with a wrench. The O-ring does the sealing, and overtightening a plastic body can crack it or distort the seat.
Q: Should I replace both valves at once?
It is good practice. Suction and discharge valves see the same chemical and the same number of cycles, so they usually wear together.
Not sure this is the right part? Send us a Picture of the Pump Plate on your pump and the CLR Marine team will confirm the correct discharge valve.