Oberdorfer 1009.71 O-ring – Buna-n Replacement Part
This is the Oberdorfer 1009.71 O-ring in Buna-N (nitrile). Oberdorfer uses static cover O-ring seals in place of cut gaskets on much of its pump range, which removes the gasket-crush variable from an assembly and lets a cover be taken off and put back without a scraper.
O-rings fail by taking a compression set, by hardening with heat and age, or by swelling when they meet a fluid the compound does not like. All three produce the same symptom, which is a joint that weeps under pressure, so the compound has to match both the fluid and the temperature it will see.
Keep spares out of sunlight and away from heat. Rubber ages on the shelf as well as in service, so rotate stock rather than keeping one ring for a decade.
Key Features
- Genuine Oberdorfer 1009.71 sealing ring
- Moulded in Buna-N (nitrile)
- Static seal design that replaces a cut gasket
- Seats in a machined groove for repeatable compression
- Inexpensive consumable that should be renewed whenever the joint is opened
Applications
- Pump cover and end plate joints
- Marine raw water and seawater circulation pumps
- Bilge, washdown and transfer pump service
- Industrial coolant and circulation systems
- Routine overhaul of Oberdorfer pump assemblies
Specifications
- Brand: Oberdorfer
- Manufacturer: Ingersoll Rand
- Manufacturer Part Number: 1009.71
- Part Type: O-ring
- Material: Buna-N (nitrile)
- Condition: New
Frequently Asked Questions
Q: Can I substitute a hardware store O-ring of the same diameter?
Diameter alone does not define the seal. Cross section and compound both matter, and a generic ring in the wrong compound is the usual cause of a repeat leak.
Q: How many does a pump take?
That depends on the model and which joints are being opened. Check your pump parts breakdown, and order a spare while you are at it.
Q: Does it need lubricating on assembly?
A light film of a compatible fluid helps it seat without rolling. Avoid petroleum grease on EPDM.
Q: Is there a shelf life?
Elastomers harden with age. Stored cool, dark and uncompressed they last for years, but a ring that has gone stiff should not be fitted.
Not sure this is the right part? Send us a Picture of the pump plate on your pump and the CLR Marine team will confirm the correct O-ring before you order.