Finish Thompson M100088 Galvanized Steel Bung Adapter
Finish Thompson supplies the M100088 as the galvanized steel bung adapter for PF, BT and TM drum pumps. It threads into the drum bung and holds the pump upright and steady in the container. It is built in galvanized steel, which is what decides where it can safely be used.
Most pumps see this part replaced well before the pump itself needs attention. Adapters are replaced when the thread is damaged or the coating has been eaten away, and a loose adapter lets the pump lean and puts a side load on the tube. Confirm the material and size against your pump before ordering, as the same position is offered in several variants across this range.
Key Features
- Galvanized Steel Bung Adapter in galvanized steel built to the original factory specification
- Galvanized steel construction with NPT thread
- Holds the pump square in the bung and limits fume escape
- Sized and finished to drop straight into the position it came from
- Inexpensive component whose failure takes the whole pump out of service
Applications
- Finish Thompson PF, BT and TM drum pumps
- Standard 55 gallon drum installations
- Steadying a drum pump that leans in the bung
- Scheduled overhaul and annual inspection of the pump
- Repair of a pump taken out of service after a leak or a loss of performance
Specifications
- Brand: Finish Thompson
- Manufacturer Part Number: M100088
- Part Type: Galvanized Steel Bung Adapter
- Material: galvanized steel
- Position: Drum bung opening
- Fits: Finish Thompson PF, BT and TM drum pumps
- Quantity Per Pump: 1
- Condition: New
Frequently Asked Questions
Q: Should anything else be replaced at the same time?
Whatever the teardown exposes. Elastomers and bushings are inexpensive and are best renewed while the pump is already apart.
Q: What causes most premature failures on this part?
Running the pump outside what it was specified for, whether that is temperature, viscosity, dry running or an incompatible chemical.
Q: Does fitting this affect the pump warranty?
Using the factory part keeps the pump to its original specification, which is what any warranty position depends on.
Q: How should the pump be flushed before service?
With a fluid known to be compatible, so the parts can be handled safely and the old chemical is not carried into the rebuild.
Not sure this is the right part? Send us a Picture of the pump plate on your pump and the CLR Marine team will confirm the correct bung adapter before you order.