Burks 115516 Case Gasket for GA4
The Burks 115516 is the genuine Burks case gasket, for GA4 pumps. A flat gasket of this kind crushes slightly as the joint is drawn together, flowing into the tooling marks on both faces so that neither liquid nor air can find a path through.
Age hardens the gasket material and the joint loses its seal. On a self-priming pump a hardened case gasket also lets air in, so the pump becomes slow to prime or loses prime between runs - a symptom that gets blamed on the foot valve far more often than on a few pence worth of gasket.
Thickness matters as much as the outline. The gasket sets the axial gap across the joint, so substituting a thicker or thinner sheet can change internal clearances and, in some housings, the running clearance to the impeller. Use the Burks part rather than something cut from stock sheet, and confirm the pump is a GA4 model.
Key Features
- Genuine Burks replacement case gasket
- Cut to the original Burks outline and bolt pattern
- Listed for GA4 pumps
- Sets the correct axial spacing across the joint
- Seals against both liquid loss and air ingress
- Renew at every teardown to avoid a repeat strip-down
Applications
- Burks GA4 pump service
- Reassembly after an impeller or seal replacement
- Curing a weep along a casing joint
- Restoring priming on a pump that has become slow to prime
- Planned maintenance spares kits
- Industrial, marine and dockside pump installations
Specifications
- Brand: Burks
- Manufacturer: Crane Pumps and Systems
- Manufacturer Part Number: 115516
- Part Type: Case Gasket
- Fits: Burks GA4
- Condition: New
Frequently Asked Questions
Q: Do I need gasket sealant as well?
Normally no. These gaskets are designed to seal dry against clean, flat machined faces, and a heavy bead of sealant can hold the joint apart or squeeze inside and break off into the pump. A thin film to hold the gasket in place during assembly is as far as most fitters go.
Q: How do I get the old gasket off without damaging the casting?
Soften it first, then use a plastic or brass scraper and work flat against the face rather than digging in. Steel blades and rotary wire wheels leave scratches across the sealing land that no new gasket will bridge.
Q: Can I cut my own from sheet material?
You can make something that holds pressure, but you will be guessing at thickness and compressibility. Since the thickness sets the spacing across the joint, a home-cut replacement can alter internal clearances in ways that only show up as lost performance.
Q: Should the bolts be retightened after the pump has run?
Check them once the pump has been up to temperature and cooled again. Gaskets relax slightly as they bed in, and a single even re-torque in a cross pattern often settles a joint that was weeping lightly.
Not sure this is the right part? Send us a Picture of the pump plate on your pump and the CLR Marine team will confirm the correct case gasket before you order.