AMT 5760-95 — 1 HP Submersible Shredder Sewage Pump, 2" NPT, 115V

 

AMT_Pump_5760-95
Basic Info   Warranty Info   Literature   Rebate Info   Video
Shipping Dimensions
14" x 12" x 21" (51.2 lbs)
Brand
AMT
Manufacturer
Gorman-Rupp
Manufacturer Part Number
5760-95
Country of Origin
United States of America
Special Order
No
Exportable
Yes
Truck Freight
No
Quantity In Stock
3
On Order
0
Your Price
$1,358.38
Qty
 

AMT 5760-95 Submersible Shredder Sewage Pump — Built for the Dirty Work Nobody Else Wants to Handle

When you're dealing with sewage, sludge, and water loaded with fibrous solids, you need a pump that doesn't flinch. The AMT 5760-95 is a 1 HP, 115-volt single-phase submersible shredder sewage pump with a 2-inch NPT discharge, built from cast iron and stainless steel to handle the punishment of real-world wastewater and solids-laden liquid applications. Whether it's a residential septic system, a commercial sewage lift station, or an industrial processing environment, this pump is designed from the ground up to keep moving when lesser equipment gives up.

 

What sets the 5760-95 apart is its engineering. The enhanced spiral shredder mechanism plate works in tandem with a carbide-tipped, semi-open cast iron impeller to break down stringy, fibrous, and sludge-type waste before it ever has a chance to clog the pump. A triplex seal system — including dual ceramic-carbon mechanical seals plus an additional lower silicon carbide shaft seal within an oil-filled chamber — provides multiple layers of protection for the motor and internal components. Because this is a submersible design, it operates quietly and requires no priming, making installation and long-term operation significantly more straightforward than comparable above-ground configurations. The motor is rated for continuous duty with automatic restart thermal overload protection for single-phase units, and it runs at 3,450 RPM on 115V, 60 Hz power at 14 amps.

Key Features

  • Cast iron pump body with stainless steel motor housing for durability and corrosion resistance
  • Carbide-tipped, semi-open cast iron impeller with self-cleaning design for handling solids without clogging
  • Enhanced spiral shredder mechanism plate — surface hardened for long-lasting cutting performance
  • Triplex seal system: dual ceramic-carbon mechanical seals plus silicon carbide lower shaft seal in oil-filled chamber
  • Submersible design — no priming required, low noise operation
  • 3,450 RPM motor rated for continuous duty
  • Single-phase thermal overload protection with automatic restart
  • Completely assembled and ready for installation
  • Unfinished power cord requires field wiring — no controls supplied

Applications

  • Residential, commercial, and industrial sewage pumping stations
  • Septic tanks and septic system transfer
  • Sewage treatment plants
  • Wastewater and dirty water drainage
  • Flood and emergency dewatering involving contaminated water
  • General liquid processing applications with small solids, fibrous material, or sludge
  • Dirty water drainage in construction, municipal, and industrial settings

Specifications

  • Model Number: 5760-95
  • Motor Power: 1 HP
  • Voltage: 115V AC, 60 Hz
  • Phase: Single Phase
  • Amperage: 14 Amps
  • Motor Speed: 3,450 RPM
  • Motor Duty: Continuous Duty
  • Discharge Port Size: 2-Inch NPT
  • Maximum Flow Rate: 130 GPM (7,200 GPH)
  • Pump Body Material: Cast Iron
  • Motor Housing Material: Stainless Steel
  • Impeller Type: Semi-open cast iron with carbide cutting tip
  • Shaft Seal: Triplex — dual ceramic-carbon mechanical seals + silicon carbide lower seal, oil-filled chamber
  • Liquid Temperature Range: 40°F to 104°F (4°C to 40°C)
  • Thermal Overload Protection: Yes — automatic restart
  • Liquid Compatibility: Non-flammable liquids; liquid content must remain above 85%
  • Pump Series: Submersible Shredder Sewage (AMT / Gorman-Rupp)


Frequently Asked Questions

Q: Does the AMT 5760-95 require priming before use?
No. The 5760-95 is a submersible pump, which means it is designed to operate fully submerged. Because it is already surrounded by liquid during operation, priming is not required and is not part of the startup procedure.

Q: Can this pump handle solid waste and fibrous materials?
Yes, that is exactly what it is built for. The spiral shredder mechanism plate and carbide-tipped impeller work together to break down stringy fibrous material, rags, and sludge-type waste before it can obstruct the pump. The impeller is also self-cleaning to reduce maintenance demands.

Q: What electrical supply does the AMT 5760-95 require?
This pump operates on 115 volts, 60 Hz, single-phase power and draws 14 amps at full load. The unit ships with an unfinished power cord that must be field-wired by a qualified electrician. No controls or float switch are included.

Q: Is the liquid content percentage important for safe operation?
Yes, this is a critical consideration. The liquid content of whatever is being pumped must remain at or above 85% at all times. Operating below that threshold can damage internal components and may void the manufacturer's warranty.

Q: What maintenance does the AMT 5760-95 typically require?
Periodic maintenance includes inspecting for leaks, clearing debris and sediment from the unit, checking for loose fasteners, and monitoring the oil-filled seal chamber. The triplex seal system is designed for long service life, but seal kits and impeller kits are available as replacement parts when service is eventually needed.

Customer Reviews
Review This product

Please log in or register to post a review this product.  All reviews will be reviewed for spam before being posted.

k 1

CLR Marine is proud to serve the boating community by providing top-quality marine supplies for safety, performance, and adventure on the water.

MORE SITE LINKS

Rebate Corner

Government

Veterans Corner

Links You May Like

Contact Manufacturer

Rebate Corner

On-line Magazines

Of Interest to boasters

Video

Sitemap

FAQ

Store Policy

Troubleshooting

Frame 99