8086 AC 3 Sources +12 Positions/DC Main +19 Position Toggle Circuit Breaker Panel - White Switches
Features:
Includes set of 30 common AC and 30 common DC labels
All AC and DC buses installed, fully pre-wired
Label backlighting pre-installed
All LEDs installed
Maximum panel Amperage
100 Amperes DC
50 Amperes AC
AC Features:
Two separate AC load groups with transfer switch to combine into one load group
Switch allows Ammeter and Voltmeter to read either AC load group
Reverse polarity indicators on both AC load groups
Ready for installation of optional 4031 AC Isolation Cover
9353, 0-150 Volt AC Voltmeter
9630, 0-50 Amp AC Ammeter
DC Features:
100 Amp C-Series circuit breaker provides main circuit protection and switching for DC branch circuits
8003, 8-16 Volt DC Voltmeter
8017, 0-100 Amp DC Ammeter
Specifications:
AC Positions: Source Selectors +12
DC Positions: Main +19
120 Volts AC
12 Volts DC
(3) 30A - (1) 50A - (6) 15A AC Circuit Breakers
(1) 100A - (13) 15A DC Circuit Breakers
*Combined AC/DC panels require a AC Insulating Cover to meet ABYC Standards
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
1612.97 |
|
|
AC 2 Sources + 12 Positions / DC Main + 19 Positions
Switches Color: White
Installed AC Breakers
(3) 16A
(1) 32A
(6) 8A
Installed DC Breakers
(1) 100A Main
(13) 15A
Voltage 230v - 12V DC
All AC and DC buses installed and fully pre-wired
Label backlighting pre-installed
ON - indicating LEDs installed in all circuit positions
100 Ampere C-Series Toggle Circuit Breaker provides main circuit protection and switching for DC branch
Maximum panel amperage - 100 Amperes AC, 50 Amperes DC
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
1613.32 |
|
|
AC Toggle Source Selector (European)
PN: 8562
White Switches
(2) 16A Double Pole Circuit Breakers Installed
(6) 8A Single Pole Circuit Breakers Installed
(1) 9354 AC Analog Voltmeter
Features:
Double pole AC main circuit breakers with installed lockout slide
Prevents connecting both AC sources simultaneously
Maximum panel amperage - 50 Amperes
Red reverse polarity indicating LED
All hot, neutral and safety ground buses installed, fully pre-wired
All circuit label positions are backlit on standard panels - No kit required
"ON" indicating LEDs installed in all circuit positions
MIL-C-5541C or equivalent immersion undercoating for lifetime corrosion resistance
Two-part polyurethane slate gray finish
Heavy 1/8" aluminum 5052 alloy
Industry standard height and width
Countersunk mounting holes throughout
=
Detailed installation instructions and cutout template included
Includes set of 30 common Large Format Labels
Over 500 individual labels available
For 230V AC Systems
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
544.25 |
|
|
AC Toggle Source Selector (European)
PN: 8566
White Switches
(2) 16A Double Pole Circuit Breakers Installed
(6) 8A Single Pole Circuit Breakers Installed
Features:
Double pole AC main circuit breakers with installed lockout slide
Prevents connecting both AC sources simultaneously
Maximum panel amperage - 50 Amperes
Red reverse polarity indicating LED
All hot, neutral and safety ground buses installed, fully pre-wired
All circuit label positions are backlit on standard panels - No kit required
"ON" indicating LEDs installed in all circuit positions
MIL-C-5541C or equivalent immersion undercoating for lifetime corrosion resistance
Two-part polyurethane slate gray finish
Heavy 1/8" aluminum 5052 alloy
Industry standard height and width
Countersunk mounting holes throughout
Detailed installation instructions and cutout template included
Includes set of 30 common Large Format Labels
Over 500 individual labels available
For 230V AC Systems
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
451.21 |
|
|
AC Toggle Source Selector (European)
PN: 8567
White Switches
(2) 16A Double Pole Circuit Breakers Installed
(2) 8A Single Pole Circuit Breakers Installed
Features:
Double pole AC main circuit breakers with installed lockout slide
Prevents connecting both AC sources simultaneously
Maximum panel amperage - 50 Amperes
Red reverse polarity indicating LED
All hot, neutral and safety ground buses installed, fully pre-wired
All circuit label positions are backlit on standard panels - No kit required
"ON" indicating LEDs installed in all circuit positions
MIL-C-5541C or equivalent immersion undercoating for lifetime corrosion resistance
Two-part polyurethane slate gray finish
Heavy 1/8" aluminum 5052 alloy
Industry standard height and width
Countersunk mounting holes throughout
Detailed installation instructions and cutout template included
Includes set of 30 common Large Format Labels
Over 500 individual labels available
For 230V AC Systems
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
289.99 |
|
|
AC Toggle Source Selector (European)
p045.19PN: 8589
White Switches
(2) 16A Double Pole Circuit Breakers Installed
(3) 8A Single Pole Circuit Breakers Installed
(1) 9354 AC Analog Voltmeter
Features:
Double pole AC main circuit breakers with installed lockout slide
Prevents connecting both AC sources simultaneously
Maximum panel amperage - 50 Amperes
Red reverse polarity indicating LED
All hot, neutral and safety ground buses installed, fully pre-wired
All circuit label positions are backlit on standard panels - No kit required
"ON" indicating LEDs installed in all circuit positions
MIL-C-5541C or equivalent immersion undercoating for lifetime corrosion resistance
Two-part polyurethane slate gray finish
Heavy 1/8" aluminum 5052 alloy
Industry standard height and width
Countersunk mounting holes throughout
Detailed installation instructions and cutout template included
Includes set of 30 common Large Format Labels
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
435.11 |
|
|
AC Toggle Source Selector (European)
PN: 8599
White Switches
(2) 16A Double Pole Circuit Breakers Installed
(2) 8A Single Pole Circuit Breakers Installed
Features:
Double pole AC main circuit breakers with installed lockout slide
Prevents connecting both AC sources simultaneously
Maximum panel amperage - 50 Amperes
Red reverse polarity indicating LED
All hot, neutral and safety ground buses installed, fully pre-wired
All circuit label positions are backlit on standard panels - No kit required
"ON" indicating LEDs installed in all circuit positions
MIL-C-5541C or equivalent immersion undercoating for lifetime corrosion resistance
Two-part polyurethane slate gray finish
Heavy 1/8" aluminum 5052 alloy
Industry standard height and width
Countersunk mounting holes throughout
Detailed installation instructions and cutout template included
Includes set of 30 common Large Format Labels
Over 500 individual labels available
For 230V AC Systems
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
290.04 |
|
|
AC 2 Sources + 9 Positions
(2) 30A Double Pole Circuit Breakers
(6) 15A Single Pole Circuit Breakers
Double pole AC main circuit breakers with installed lockout slide
Prevents connecting both AC sources simultaneously
Maximum panel amperage - 50 Amperes
Red reverse polarity indicating LED
All hot, neutral and safety ground buses installed, fully pre-wired
All circuit label positions are backlit on standard panels - No kit required
"ON" indicating LEDs installed in all circuit positions
MIL-C-5541C or equivalent immersion undercoating for lifetime corrosion resistance
Two-part polyurethane slate gray finish
Heavy 1/8" aluminum 5052 alloy
Industry standard height and width
Countersunk mounting holes throughout
Detailed installation instructions and cutout template included
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
544.62 |
|
|
AC 2 Sources + 4 Positions
(2) 30A Double Pole Circuit Breakers
Double pole AC main circuit breakers with installed lockout slide
Prevents connecting both AC sources simultaneously
Maximum panel amperage - 50 Amperes
Red reverse polarity indicating LED
All hot, neutral and safety ground buses installed, fully pre-wired
All circuit label positions are backlit on standard panels - No kit required
"ON" indicating LEDs installed in all circuit positions
MIL-C-5541C or equivalent immersion undercoating for lifetime corrosion resistance
Two-part polyurethane slate gray finish
Heavy 1/8" aluminum 5052 alloy
Industry standard height and width
Countersunk mounting holes throughout
Detailed installation instructions and cutout template included
Includes set of 30 common Large Format Labels
Over 500 individual labels available
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
290.04 |
|
|
AC 2 Sources + 9 Positions
(2) 30A Double Pole Circuit Breakers
(6) 15A Single Pole Circuit Breakers
Double pole AC main circuit breakers with installed lockout slide
Prevents connecting both AC sources simultaneously
All hot, neutral and safety ground buses installed, fully pre-wired
All circuit label positions are backlit on standard panels - No kit required
"ON" indicating LEDs installed in all circuit positions
MIL-C-5541C or equivalent immersion undercoating for lifetime corrosion resistance
Two-part polyurethane slate gray finish
Heavy 1/8" aluminum 5052 alloy
Industry standard height and width
Countersunk mounting holes throughout
Detailed installation instructions and cutout template included
Includes set of 30 common Large Format Labels
Over 500 individual labels available
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
451.21 |
|
|
Blue Sea Systems Products on Water or Land
In addition to the marine industry, Blue Sea Systems products can be found on emergency vehicles, RVs, agricultural equipment, off-road vehicles, and other industries where rugged, dependable products are required.
7650 Add-A-Battery
Add-a-Battery simplifies switching and automates charging for a complete two battery bank management solution. The Dual Circuit Plus™ Battery Switch isolates engine and house circuits and combines battery banks for emergency starting.
WeatherDeck 4376 Water Resistant Circuit Breaker Panel
The 4376 WeatherDeck is a water resistant circuit breaker panel with 6 positions. It is rated IP67 for temporary immersion for 30 minutes. The 4376 is designed for flybridge and open cockpit applications.
5025 ST Blade Fuse Block with Cover
The 5025 ST Blade Fuse Block with a clear, insulating cover has 6 circuits and a negative bus. The 5025 can be used for 24-circuits and has a positive distribution bus with a #10-32 stud. Models are available with or without a cover.
7748 SafetyHub 150 Fuse Block
The SafetyHub 150 is an ignition protected fuse block with screw termination. It is safe for use on gasoline powered boats, reduces wiring connections, and consolidates up to ten fused circuits. It can be used for Main or Branch DC power distribution.
|
|
|
8032 AC Toggle Source Selector 120V AC - 30AMP - White Switches
Features:
Double pole AC main circuit breakers with installed lockout slide
Prevents connecting both AC sources simultaneously
Maximum panel amperage - 50 Amperes
Red reverse polarity indicating LED
All hot, neutral and safety ground buses installed, fully pre-wired
All circuit label positions are backlit on standard panels - No kit required
"ON" indicating LEDs installed in all circuit positions
Specifications:
Source Selection: 2
Nominal Voltage: 120v AC
Height: 3.75"
Width: 5.25"
Included:
(2) 7238 A-Series White Toggle Circuit Breaker - Double Pole 30A
(1) 8031 Basic AC Panel Label Set - 30 Labels
(2) 8034 LED - 120v AC Green
(1) 8066 LED - 120v AC Red
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
205.19 |
|
|
8413 - Metal AC/DC Panel with M2 Vessel Systems Monitor & 22 Circuit Breakers (15A)
Complete AC/DC panel with M2 Vessel Systems Monitor (VSM) that provides monitoring of AC systems, DC systems, tanks, and bilges in one (1) compact OLED meter with NMEA 2000 connectivity.
Features:
ON indicating LEDs installed in all circuit positions
Backlit label positions
Circuit identification label sets included
White toggle circuit breakers match existing traditional panels
AC and DC buses installed, fully pre-wired, and ready for installation
The panel is marked to comply with ABYC standards
Red reverse polarity indicated LED
Technical Specifications:
Nominal Voltage - 120V AC and 12/24V DC
Positions - 8 AC Positions + Main and 14 DC Positions + Main
Meter - M2 Vessel Systems Monitor
Dimensions (H x W x D) - 9.25" x 15.77" x 3" (235 x 400.56 x 76.2mm)
In the Box:
8413 Panel
Labels
Mounting hardware
*Sold as Individual
|
1278.94 |
|
|
AC Toggle Source Selector (European)
PN: 8132
White Switches
(2) 16A Double Pole Circuit Breakers
Features:
Double pole AC main circuit breakers with installed lockout slide
Prevents connecting both AC sources simultaneously
Maximum panel amperage - 50 Amperes
Red reverse polarity indicating LED
All hot, neutral and safety ground buses installed, fully pre-wired
All circuit label positions are backlit on standard panels - No kit required
"ON" indicating LEDs installed in all circuit positions
MIL-C-5541C or equivalent immersion undercoating for lifetime corrosion resistance
Two-part polyurethane slate gray finish
Heavy 1/8" aluminum 5052 alloy
Industry standard height and width
Countersunk mounting holes throughout
=
Detailed installation instructions and cutout template included
Includes set of 30 common Large Format Labels
Over 500 individual labels available
For 230V AC Systems
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
209.29 |
|
|
AC Toggle Source Selector (European)
PN: 8598
White Switches
(3) 16A Double Pole Circuit Breakers Installed
(1) 32A Double Pole Circuit Breaker Installed
Features:
Double pole AC main circuit breakers with installed lockout slide
Prevents connecting both AC sources simultaneously
Maximum panel amperage - 50 Amperes
Red reverse polarity indicating LED
All hot, neutral and safety ground buses installed, fully pre-wired
All circuit label positions are backlit on standard panels - No kit required
"ON" indicating LEDs installed in all circuit positions
MIL-C-5541C or equivalent immersion undercoating for lifetime corrosion resistance
Two-part polyurethane slate gray finish
Heavy 1/8" aluminum 5052 alloy
Industry standard height and width
Countersunk mounting holes throughout
Detailed installation instructions and cutout template included
Includes set of 30 common Large Format Labels
Over 500 individual labels available
For 230V AC Systems
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
344.82 |
|