AC Turbo Electric Pump
Super high capacity with inflation of 34 cubic feet per minute. Quickly inflates & deflates all large-volume inflatables. AC power of 120V. Includes three universal adapters for compression & Boston valves and a 6' power cord. Max. the pressure of 2.3 PSI.
Features:
The fastest way to quickly inflate and deflate all large-volume inflatables
Includes 3 universal adapters and a 6' power cord
2.3 PSI max pressure
|
36.61 |
|
|
March Pump's AC-5B-MD Beer Pump is an American seal-less centrifugal magnetic drive pump ideal for homebrewing. It is capable of generating a maximum flow of 17 gallons per minute at 1 foot, and its maximum head is 27 Feet (or around 11PSI). The standard wet end (the materials that come into contact with the solution) is composed of Polysulfone, Buna N, Ceramic, and Ceramic Magnet. The inlet connection is 1 inch female pipe thread, and the outlet is 0.5 inch male pipe thread. The standard motor is a 1 Phase 115V or 230V 0.125 Horsepower fan cooled motor, which can be run on either 50 or 60 hertz (there are performance differences between the hertz options). The maximum internal pressure the pump can tolerate is 50PSI, and the maximum liquid temperature is 225 Fahrenheit or 107 Celsius. The AC-5B-MD Beer Pump pumps Hot Water and Hot Wort.
Unit System 60Hz 50Hz Max Flow
17 GPM
60 LPM
Max Head
27 FT
6 M
Power
.125 HP
.093 KW
Electrical
115V 60Hz
Type
Metering Pump
Inlet
1"FPT
Outlet
1/2"MPT
Wet End
Polysulfone (Front and Rear Housing, Impeller), Stainless Steel (Magnet Shell, Shaft), Buna N (O-Ring), Ceramic (Thrust Washers)
Can handle liquids of 225F
Materials are FDA Food Compliant
American Made
Components are UL Recognized
|
580.13 |
|
|
Applications for the AC-4C-MD Magnetic Drive Pump include electronic medical equipment, etching machines, photo processing equipment, hospital thermal blankets, and food heating cabinets.
March Pump's industrial AC-4C-MD is an American seal-less centrifugal magnetic drive pump ideal for applications such as chemical recirculation, chemical transfer, and scrubber systems. It is capable of generating a maximum flow of 14 gallons per minute at 1 feet, and its maximum head is 21.5 Feet (or around 9PSI). The standard wet end (the materials that come into contact with the solution) is composed of Polypropylene, Buna N, Ceramic, and Ceramic Magnet. The inlet connection is 1 inch female pipe thread, and the outlet is 0.75 inch male pipe thread. The standard motor is a 1 Phase 115V or 230V 0.83 Horsepower fan cooled motor, which can be run on either 50 or 60 hertz (there are performance differences between the hertz options). The maximum internal pressure the pump can tolerate is 50PSI, and the maximum liquid temperature is 190 Fahrenheit or 87 Celsius. The March AC-4C-MD centrifugal magnetic drive pump is capable of handling mildly or highly corrosive chemicals, acids, and solvents.
Unit System 60Hz 50Hz Max Flow
14 GPM
50 LPM
Max Head
21.5 FT
4.7 M
Power
.083 HP
.062 KW
Electrical
115V 50/60HZ or 230V 50/60HZ
Type
Centrifugal Mag Drive
Inlet
1"FPT
Outlet
1/2"MPT
Wet End
Polypropylene (Front and Rear Housing, Impeller), Buna N (O-Ring), Ceramic (Shaft, Thrust Washers), Ceramic Magnet
Available with 750 Priming Chamber
|
438.75 |
|
|
March AC-5SSB-MD Magnetic Drive Beer Pump
March Pump’s AC-5SSB-MD Beer Pump is an American seal-less centrifugal magnetic drive pump ideal for homebrewing. It is capable of generating a maximum flow of 17 gallons per minute at 1 foot, and its maximum head is 27 Feet (11PSI).
March Pump’s AC-5SSB-MD Beer Pump is an American seal-less centrifugal magnetic drive pump ideal for homebrewing. It is capable of generating a maximum flow of 17 gallons per minute at 1 foot, and its maximum head is 27 Feet (11PSI). The standard wet end (the materials that come into contact with the solution) is composed of Stainless Steel, Polysulfone, Buna N, Ceramic, and Ceramic Magnet. The inlet connection is 1 inch female pipe thread, and the outlet is 1/2 inch male pipe thread. The standard motor is a 1 Phase 115V or 230V 0.125 Horsepower fan cooled motor, which can be run on either 50 or 60 hertz (there are performance differences between the hertz options). The maximum internal pressure the pump can tolerate is 200PSI, and the maximum liquid temperature is 250 Fahrenheit or 121 Celsius.
Electrical/Air: 115V 50/60Hz
Inlet: 1"FPT
Outlet: 1/2"MPT
Wet End: Polysulfone (Impeller), 316 Stainless Steel (Front and Rear Housing, Magnet Shell, Shaft), Buna N (O-Ring), Ceramic (Thrust Washers)
Can handle liquids of 250F: Materials are FDA Food Compliant
American Made: Components are UL Recognized
P/N: 0150-0208-0100 (115V)
|
860.16 |
|
|
March AC-5SSB-MD Magnetic Drive Beer Pump 230V
March Pump’s AC-5SSB-MD Beer Pump is an American seal-less centrifugal magnetic drive pump ideal for homebrewing. It is capable of generating a maximum flow of 17 gallons per minute at 1 foot, and its maximum head is 27 Feet (11PSI).
March Pump’s AC-5SSB-MD Beer Pump is an American seal-less centrifugal magnetic drive pump ideal for homebrewing. It is capable of generating a maximum flow of 17 gallons per minute at 1 foot, and its maximum head is 27 Feet (11PSI). The standard wet end (the materials that come into contact with the solution) is composed of Stainless Steel, Polysulfone, Buna N, Ceramic, and Ceramic Magnet. The inlet connection is 1 inch female pipe thread, and the outlet is 1/2 inch male pipe thread. The standard motor is a 1 Phase 115V or 230V 0.125 Horsepower fan cooled motor, which can be run on either 50 or 60 hertz (there are performance differences between the hertz options). The maximum internal pressure the pump can tolerate is 200PSI, and the maximum liquid temperature is 250 Fahrenheit or 121 Celsius.
Electrical/Air: 230V 50/60Hz
Inlet: 1"FPT
Outlet: 1/2"MPT
Wet End: Polysulfone (Impeller), 316 Stainless Steel (Front and Rear Housing, Magnet Shell, Shaft), Buna N (O-Ring), Ceramic (Thrust Washers)
Can handle liquids of 250F: Materials are FDA Food Compliant
American Made: Components are UL Recognized
P/N: 0150-0208-0200 (230V)
|
788.63 |
|
|
March 0150-0251-0100 Magnetic Drive Pump AC-5M-MD
March Pump’s industrial AC-5M-MD is an American seal-less centrifugal magnetic drive pump ideal for applications such as chemical recirculation, chemical transfer, and scrubber systems. It is capable of generating a maximum flow of 17 gallons per minute at 1 feet, and its maximum head is 27 Feet (11PSI). The pump is Ignition Protected per SAE J1171 and ISO 8846, and has extended run dry protection thru the use of a carbon bushing. It is capable of 48,000 BTU a hour.
Max Flow: 17 GPM
Max Head: 27 FT
Power: 0.125 HP
Electrical/Air: 115V 50/60Hz
Motor
3 Foot Cord
60Hz: 1Ph 115V 0.125HP/0.093kW, 2.1 AMPS, 3450 RPM
50Hz: 1Ph 115V 0.125HP/0.093kW, 1 AMPS, 2850 RPM
Inlet: 1"FPT
Outlet: 1/2"MPT
Wet End: Polypropylene (Rear Housing, Impeller), Noryl (Front Housing) Buna N (O-Ring), 316 Stainless Steel (Shaft), Carbon (Impeller Bushing) Ceramic (Thrust Washers), Ceramic Magnet
Max Internal Pressure: 50 PSI / 3.4 bar
Max Liquid Temperature: 190 °F / 87 °C
Ignition Protected per SAE J1171 and ISO 8846: UL Listed Motor
This pump is capable of generating a maximum flow of 17 gallons per minute at 1 feet, and its maximum head is 27 Feet (11PSI). It is capable of 48,000 BTU a hour. The standard wet end (the materials that come into contact with the solution) is composed of Polypropylene, Noryl, Buna N, Carbon, 316 Stainless Steel, Ceramic, and Ceramic Magnet. The inlet connection is 1 inch female pipe thread, and the outlet is 1/2 inch male pipe thread. The standard motor is a 1 Phase 115V or 230V 0.125 Horsepower fan cooled motor, which can be run on either 50 or 60 hertz (there are performance differences between the hertz options). The maximum internal pressure the pump can tolerate is 50PSI, and the maximum liquid temperature is 190 Fahrenheit or 87 Celsius.
The pump is Ignition Protected per SAE J1171 and ISO 8846. The impeller has a carbon bushing allowing the pump to run dry longer before suffering damage.
|
458.50 |
|
|
March 0150-0040-1000 Magnetic Drive Pump AC-5M-MD
March Pump’s industrial AC-5M-MD is an American seal-less centrifugal magnetic drive pump ideal for applications such as chemical recirculation, chemical transfer, and scrubber systems. It is capable of generating a maximum flow of 17 gallons per minute at 1 feet, and its maximum head is 27 Feet (11PSI). The pump is Ignition Protected per SAE J1171 and ISO 8846, and has extended run dry protection thru the use of a carbon bushing. It is capable of 48,000 BTU a hour.
Max Flow: 64.4 LPM
Max Head: 8.2 M
Power: 0.093 KW
Electrical/Air: 230V 50/60Hz
Motor
3 Foot Cord
60Hz: 1Ph 230V 0.125HP/0.093kW, 2.1 AMPS, 3450 RPM
50Hz: 1Ph 230V 0.125HP/0.093kW, 1 AMPS, 2850 RPM
Inlet: 1"FPT
Outlet: 1/2"MPT
Wet End: Polypropylene (Rear Housing, Impeller), Noryl (Front Housing) Buna N (O-Ring), 316 Stainless Steel (Shaft), Carbon (Impeller Bushing) Ceramic (Thrust Washers), Ceramic Magnet
Max Internal Pressure: 50 PSI / 3.4 bar
Max Liquid Temperature: 190 °F / 87 °C
Ignition Protected per SAE J1171 and ISO 8846: UL Listed Motor
This pump is capable of generating a maximum flow of 17 gallons per minute at 1 feet, and its maximum head is 27 Feet (11PSI). It is capable of 48,000 BTU a hour. The standard wet end (the materials that come into contact with the solution) is composed of Polypropylene, Noryl, Buna N, Carbon, 316 Stainless Steel, Ceramic, and Ceramic Magnet. The inlet connection is 1 inch female pipe thread, and the outlet is 1/2 inch male pipe thread. The standard motor is a 1 Phase 115V or 230V 0.125 Horsepower fan cooled motor, which can be run on either 50 or 60 hertz (there are performance differences between the hertz options). The maximum internal pressure the pump can tolerate is 50PSI, and the maximum liquid temperature is 190 Fahrenheit or 87 Celsius.
The pump is Ignition Protected per SAE J1171 and ISO 8846. The impeller has a carbon bushing allowing the pump to run dry longer before suffering damage.
|
488.50 |
|
|
March AC-3CP-MD MC Pump W/115V Motor(Mcmillan)
|
304.20 |
|
|
March AC-5AP-MD 115V +Pump 1X3/4 Smooth Ports
This item is 'build to order'. Please contact us for lead time.
|
593.93 |
|
|
March 0130-0113-0100 WET END KIT For AC-3CP-MD
March Pump Wet End Assembly Includes All Parts except Motor, Bracket and Drive Magnet
|
109.20 |
|
|
Turbo Triplex Pump with Gauge & 2 Hoses
Triple-action high-pressure pump for all Solstice inflatable SUPs, docks, platforms & more. Extra long body & high airflow piston for seamless inflation. Switch to change from triple, double, or single action inflation. Ergonomic handle and pump foot anchors. Durable hand pump equipped with shock-proof built-in pressure gauge. Provides pressure up to 26 PSI. Includes (2) types of hoses: universal HR valve & compression/Boston valves.
Features:
Triple actions, high-pressure handpump
Changes easily from a triple, dual, or single action
Extra long body and dual chamber design
Universal for all standard HR valves
Includes the second hose for low-pressure inflatables
26 PSI max pressure
|
88.78 |
|
|
No matter whether you are an experienced boater looking for a replacement pump or a manufacturer specifying pumps for your marine application, we are prepared to provide you with the support you need. And no matter where you work or live, access to our products, services, spare parts and support are never far away. In fact, you will find SPX FLOW's Johnson Pump marine brand represented in every major industrial country of the world today and in more than sixty nations altogether.
SHOP JOHNSON PUMP
The Aqua Jet five chamber diaphragm pump provides the perfect water pressure or deck wash solution for both small and medium sized leisure and commercial boats as well as mobile homes, campers and summer homes.
Quiet and pulsation-free even at low speeds. Efficient and compact, Aqua Jet pumps are particularly suitable where low amperage and sound levels in relation to water flow are placed at a premium-such as in shower and galley applications. Integrated pressure switch turns pump on and off automatically when tap is opened and closed. Operates in fresh or sea water.
SHOP THE Aqua Jet five chamber diaphragm pump
Specials Closeouts Remanufactured Rebates
|
|
|
High-Capacity AC Pump
High-capacity AC electric pump for all inflatables. Designed for home or travel use with AC electric system. Equipped with both inflate & deflate ports. Comes with a multi-use adapter kit for compression valves. No batteries required - AC operation.
Features:
For all inflatables
Inflates and deflates
No batteries required - AC operation
Complete with multi-use adapter kit
|
22.72 |
|
|
High Capacity DC Electric Pump
High-capacity DC electric pump for all inflatables. Plugs into any 12V car or boat accessory outlet. Equipped with both inflate & deflate ports. Comes with a multi-use adapter kit for compression & Boston valves.
Features:
For all inflatables
Inflates and deflates
Complete with multi-use adapter kit
Plugs into car/boat accessory outlet
|
14.93 |
|
|
Walbro FRA-1-1 Electric Fuel Pump
Voltage: 12V DC
Weight: 1.63 lb
Minimum Flow Rate: 20 gph
Dry Lift: 24"
Service Life: 5,000+ hr
Fuse: 5A
Current Draw: 2.0 Amps
Inlet/Outlet: 1/8-27 NPSF
Inlet Filter Screen: 70 Micron
Magnetic Trap: None
Outlet Check Valve: No
Maximum Output Pressure: 4.0 - 7.0 psi
The FRA Series electric fuel pump operates at a constant frequency — it will continue to cycle as long as electric power is supplied.
If there is no demand for fuel, the pump will build pressure in the fuel delivery line - up to its rated maximum pressure - and continue to cycle, but with no fuel output.
As such, it is not well-suited for continuous operation/low demand applications such as heater or stove systems, since it will constantly make noise, and have a shortened service life due to high cycling.
For stove/heater and continuous duty applications, use the Walbro FRD series of pumps, which addresses these issues. See Related Products, below.
An FRA pump can be used, however, to fill a gravity-feed day tank commonly used in diesel stove and heater installations.
FRA pumps incorporate a new piston mechanism which, unlike rubber diaphragms, is not affected by modern, high-tech fuel blends.
The FRA is designed to serve as a primary pump (replacing a mechanical fuel pump) or as an auxilliary fuel pump (assisting the existing pump) for internal combustion engines.
The pump self-regulates to its pre-set pressure, pumping more or less fuel as the delivery pressure (head) varies.
FRA pumps are commonly used as replacements for failed mechanical fuel pumps on older engines, where the owner doesn't want to continue using a pump with a rubber diaphragm susceptable to degradation by modern alcohol fuel blends.
They are also commonly used in open flow, low head applications such as fuel polishing.
• Non-adjustable maximum output pressure is factory pre-set in the ranges indicated below
• Output pressure can be further regulated by screwing in, or placing in-line, an adjustable pressure regulator such as the HOL 12-804
• FRA provides low cost with good durability
• Compatible with all commercially available pump grade gasoline, gasoline-alcohol blends, diesel, and bio-diesel fuels
• Continuous duty life (diesel fuel): >5,000 hours
• Flow rates as high as 52 gph, but 30 gph is a more typical maximum
• Current draw averages less than 2 amps
• Self-priming to at least 2 feet; maximum dry run time is 4 hours
• Inlet (bottom)/Outlet (top): 1/8-27 NPSF (Dryseal American National Standard Straight Pipe Thread) — will accept NPT tapered fittings without leaking, thread sealant recommended
• No internal filter - a 70 micron, or finer, pre-filter is recommended
• USCG 16623-1 and 16623-2 approved; ignition protected
• Dichromate coating passes 96 hour salt spray test - not recommended where exposed to saltwater
• Dimensions: 5.43"H x 2.76"Dia.
• Note - a suffix number (typically -1 or -2) in part number refers to type of packaging
• Made in USA
Technical
Selecting among the Walbro FR Series electric fuel pumps:
• All the FR electric pumps provide fuel until the fuel demand decreases, or flow is restricted - but they have different mechanisms for doing so.
FR pumps will cycle (pump) until they build up the pressure (head) in the outflow line - with an accompanying decrease in fuel flow - and reach their factory preset maximum pressure.
At this point, constant frequency pumps like the FRA will continue cycling - but no fuel will flow.
Variable frequency pumps, like the FRB and FRD, will slow and eventually stop cycling as the pressure builds.
If the pressure on the outflow side of the pump drops, both types of pump will start supplying fuel again.
• Choosing an FR Series pump is often less dependent on the application, and more a matter of user preference:
— FRA pumps are lower cost, basic models.
They have no built-in filter, and their constant cycling means electric current draw is constant - regardless of output, they are always making noise, they typically have a shorter lifespan (higher wear), and they can wear unevenly as the stroke can be shortened when operating near their maximal pressure.
— FRB and FRD pumps have a more expensive variable frequency circuit board, always use their full stroke length - so wear is evenly distributed, do not always operate at full capacity/maximal cycling — so less wear, longer life, less noise, and lower average current draw.
Additionally, the FRB models include a built-in/replaceable 70 micron mesh filter, so the user doesn't need to supply a pre-filter.
• What the FR fuel pump is designed to do:
— In carbureted applications - The FRA and FRB fuel pumps self-regulate to their maximum output pressure when the carburetor bowl is full, and respond to float movement in the carburetor as required.
When the engine demands more fuel, the pump increases its flow rate.
When the engine demand drops, the pump reduces its flow rate.
— In diesel applications - The FRA and FRB pumps will deliver fuel to the diesel injector pump, assuring a positive pressure at the injector pump inlet.
These pumps are designed to refill diesel filters after service or replacement.
— In transfer applications, including fuel polishing, FRA and FRB pumps run continuously, as long as electrical power is supplied to the pump, and output back pressure is low.
— In diesel heater and stove applications, the task-specific FRD pumps will slow their cycling rate to deliver only the fuel required by the stove fuel metering valve ("carburetor").
FRD pumps can also fill day tanks in gravity feed installations.
|
331.94 |
|