Lynx Power-In Class-T M10 Terminals
The Lynx Class-T Power In connects and fuses up to two strings of lithium batteries. It features a positive and negative busbar, connections for two Class-T fuses, and a connection to ground the DC system. The Class T-fuses, are available in 225A, 250A, 350A, and 400A (must be purchased separately).
For installations using three or more strings of lithium batteries, use multiple Lynx Class-T modules. As a core component of the Lynx Distribution system, the Lynx Class-T seamlessly integrates with all other M10 Lynx products.
The Lynx Distribution System
The Lynx Distribution System is a modular busbar system that incorporates DC connections, distribution, fusing, and battery monitoring and/or lithium battery management.
The Lynx Distribution System Consists of the Following Parts
Lynx Power In
A positive and negative busbar with four batteries or DC equipment connections.
Lynx Distributor
A positive and negative busbar with four fused connections for batteries or DC equipment and fuse monitoring is available in two versions.
Lynx Shunt VE.Can
A positive busbar with a space for a main system fuse and a negative busbar with a shunt for battery monitoring. It has VE.Can communication for monitoring and setup with a GX device.
Lynx Smart BMS
For use together with Victron Energy Smart Lithium batteries. It contains a positive busbar with a contactor driven by a battery management system (BMS) and a negative busbar with a shunt for battery monitoring.
It has Bluetooth communication for monitoring and setup via the VictronConnect App and VE.Can communication for monitoring with a GX device and the VRM portal. Available as a 1000A model with M10 busbars.
Specifications
Power:
Voltage Range: 9 - 60Vdc
Current Rating: 1000Adc continuous
Connections: M10
Busbar: 3/8”
Physical:
Enclosure Material: ABS
Enclosure Dimensions (H x W x D): 279 x 169 x 97mm
Unit Weight: 2.1 kg
Busbar Material: Tinned copper
Busbar Dimensions (H x W): 8 x 30mm
Environmental:
Operating Temperature Range: -40°C to +60°
Storage Temperature Range: -40°C to +60°
Humidity: Max. 95% (non-condensing)
Protection Class: IP20
Please contact your dealer for any returns, repairs or support issues related to this product.
|
204.00 |
|
|
Lynx Power-In with M10 Terminals
The Lynx Power In contains a positive and negative busbar with 4 connections for batteries, loads, or chargers and a ground connection. It is part of the Lynx Distribution System. This version is a M10 busbar.
Note that M10 refers to the busbar connection joints where the modules are connected. The fuse and cable connections are always M8.
The Lynx Distribution System
The Lynx Distribution System is a modular busbar system that incorporates DC connections, distribution, fusing, and battery monitoring and/or lithium battery management.
The Lynx Distribution System Consists of the Following Parts
Lynx Power In
A positive and negative busbar with four batteries or DC equipment connections.
Lynx Distributor
A positive and negative busbar with four fused connections for batteries or DC equipment and fuse monitoring, is available in two versions.
Lynx Shunt VE.Can
A positive busbar with a space for a main system fuse and a negative busbar with a shunt for battery monitoring. It has VE.Can communication for monitoring and setup with a GX device.
Lynx Smart BMS
For use together with Victron Energy Smart Lithium batteries. It contains a positive busbar with a contactor driven by a battery management system (BMS) and a negative busbar with a shunt for battery monitoring.
It has Bluetooth communication for monitoring and setup via the VictronConnect App and VE.Can communication for monitoring with a GX device and the VRM portal. Available as a 1000A model with M10 busbars.
Please contact your dealer for any returns, repairs or support issues related to this product.
|
193.80 |
|
|
Lynx Power-In
The lynx power in module is used to connect batteries via an external fuse. It can be useful if you have multiple parallel strings. Due to the extremely high short circuit current potential of most battery banks, it is suggested to use an external fuse system with an appropriate fault current interruption rating (such as an NH HRC).
The Power In contains a negative and positive DC bus-bar with M8 bolts in which to connect batteries cables. It can take cables up to 22 mm in diameter through the bottom entry guides, and no limit via the two side connections.
Warranty Info
WARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
Please contact your dealer for any returns, repairs or support issues related to this product.
|
169.32 |
|
|
Lynx Distributor with M10 Terminals
The Lynx Distributor contains a positive and a negative busbar. The positive busbar has four fuse-protected connections with fuse monitoring. The negative busbar has four connections and a ground connection. This model is part of the Lynx distribution and is a M10 busbar model. Note that M10 refers to the busbar connection joints where the modules are connected. The fuse and cable connections are always M8.
The Lynx Distributor has a power LED and four fuse status indication LEDs. If connected to a Lynx Smart BMS, up to 4 Lynx Distributors can send fuse status information to the Lynx Smart BMS. This feature is not available when connected to a Lynx Shunt VE.Can.
Features:
1000A model with M10 busbars
The Lynx Distributor ships together with a 40cm RJ10 cable, which provides power to the Lynx Distributor and is also used to transmit data if connected to a Lynx Smart BMS
The Lynx Distributor is designed to hold MEGA fuses
If the Lynx Distributor is connected to a Lynx Smart BMS, it can be monitored and set up with the VictronConnect App
Up to 4 connected Lynx distributors can be monitored with a GX device if connected to a Lynx Smart BMS
The Lynx Distribution System
The Lynx Distribution System is a modular busbar system that incorporates DC connections, distribution, fusing, and battery monitoring and/or lithium battery management.
The Lynx Distribution System Consists of the Following Parts
Lynx Power In
A positive and negative busbar with four batteries or DC equipment connections.
Lynx Distributor
A positive and negative busbar with four fused connections for batteries or DC equipment and fuse monitoring, is available in two versions.
Lynx Shunt VE.Can
A positive busbar with a space for a main system fuse and a negative busbar with a shunt for battery monitoring. It has VE.Can communication for monitoring and setup with a GX device.
Lynx Smart BMS
For use together with Victron Energy Smart Lithium batteries. It contains a positive busbar with a contactor driven by a battery management system (BMS) and a negative busbar with a shunt for battery monitoring.
It has Bluetooth communication for monitoring and setup via the VictronConnect App and VE.Can communication for monitoring with a GX device and the VRM portal. Available as a 1000A model with M10 busbars.
Please contact your dealer for any returns, repairs or support issues related to this product.
|
266.22 |
|
|
Lynx Smart BMS 1000 Battery Management System for Lithium Smart Batteries
The Lynx Smart BMS is a dedicated Battery Management System (BMS) for the Victron Lithium Battery Smart batteries. These batteries are Lithium Iron Phosphate (LiFePO4) batteries and are available in 12.8 V or 25.6 V in various capacities. They can be connected in series, parallel, and series/parallel so that a battery bank can be built for system voltages of 12V, 24 V, or 48 V. The maximum number of batteries in one system is 20, which results in a maximum energy storage of 84 kWh in a 12 V and up to 102 kWh in a 24 V1) and 48 V1) system.
Out of the various available BMSes, the Lynx Smart BMS is the most feature-rich and complete option and integrates seamlessly into the Lynx Distributor system. This model is a 1000 A (M10) version.
Built-in 1000 A Contactor
The contactor acts as a secondary safety system to protect the battery in case the primary controls (ATC, ATD, and/or DVCC) fail to disable loads and/or chargers when required and is also suitable as a remote controllable main system switch.
Pre-charge Circuit
In addition to the contactor, a built-in pre-charge circuit prevents high inrush currents when connecting a capacitive load such as a MultiPlus/Quattro or other inverter, eliminating the need for external pre-charging.
Monitoring and Control
Monitor and control the BMS via Bluetooth using the VictronConnect App or a GX device such as a Cerbo GX and the VRM Portal. A built-in battery monitor that operates similarly as the other Victron Energy battery monitors, provides data such as state of charge, voltage, current, historical data, status info, and more in real-time and with instant readout even without the need to connect to the BMS, allowing diagnostic at a glance.
DVCC closed Loop Control as Well as ATC/ATD Contacts
Compatible Victron inverters/chargers and solar chargers are automatically controlled via a connected GX device and DVCC. The ATC/ATD contacts can be used to control other chargers and loads that have a remote on/off port.
Programmable Relay
The relay can be used either as an alarm relay (combined with the pre-alarm) or to control an alternator via its external regulator (ignition cable). In Alternator ATC mode, the relay will only activate when the contactor is closed. Alternator ATC contact of the alternator opens first and then with a delay of 2 seconds the contactor. These 2 seconds ensure that the alternator is switched off before the battery is disconnected from the system.
AUX Terminal
The advantage of the onboard auxiliary power supply (1.1 A @ system voltage) is to provide power to specific loads (i.e. a GX device) after the BMS has shut down the loads in the event of a low cell voltage event. If no charge voltage is detected within 5 minutes, the BMS, including the AUX connection switches off.
VE.Can and NMEA 2000 Data Communication
VE.Can allows for easy connection (standard RJ45 network cable) and communication with a GX device. Since the CANbus protocol is based on NMEA 2000 (and J1939), it is easy to integrate into a marine network and feed a marine MFD with data (requires a VE.Can to NMEA 2000 micro-C male cable).
Lynx Distributor Fuse Monitoring
Read out the fuse status and receive an alarm in case a fuse is blown. The Lynx Smart BMS monitors up to 4 connected Lynx Distributors and their fuses via VictronConnect or a GX device 1) To reduce the required balancing time, we recommend using as many different batteries in series as possible for the application. 24 V systems are best built using 24 V batteries, and a 48 V system.
This System Contains the Following Components:
Lynx Distributor with 2 fused paralleled lithium-ion smart batteries.
Lynx Smart BMS with BMS, contactor, and battery monitor
A second Lynx distributor provides fused connections for inverter/charger(s), loads and chargers (additional modules can be added if more connections are needed)
A Cerbo GX (or other GX device) to read out the Lynx Smart BMS and Lynx Distributor data.
Power Specifications:
Battery Voltage Range: 9 – 60 VDC
Maximum Input Voltage: 75 VDC
Supported System Voltages: 12, 24, or 48 V
Reverse Polarity Protection: No
Main Safety Contactor Continuous Current Rating: 1000 A continuous
Main Safety Contactor Peak Current Rating: 1200 A for 5 minutes
Power Consumption OFF Mode: 0.3 mA for all system voltages
Power Consumption in Standby Mode: Approximately 0.6 W (50 mA at 12 V)
Power Consumption in ON Mode: Approx. 2.6 W (217 mA at 12 V) depending on the state of the relays
Approximately 4.2 W (350 mA at 12 V) depending on the state of the relays
Minimum Load Resistance for Pre-Charging: 10 Ω and above for 12 V systems, 20 Ω and above for 24 V and 48 V systems
AUX Output Maximum Current Rating: 1.1 A continuous, protected by resettable fuse
Allow-to-Charge Port Maximum Current Rating: 0.5 A at 60 VDC, protected by a resettable fuse
Allow-to-Discharge Port Maximum Current Rating: 0.5 A at 60VDC, protected by a resettable fuse
Alarm Relay (SPDT) Maximum current Rating: 2 A at 60 VDC
Connections:
Busbar: M10 (Torque: 17 Nm)
VE.Can: RJ45
I/O: Removable multi-connector with screw terminals
Battery BTV Cables: Male and female circular 3-pole connector with M8 screw ring Up to 20 batteries can be connected in one system Lynx Distributor fuse monitoring (up to 4 modules) RJ10 (cable ships with each Lynx Distributor)
Physical Specifications:
Enclosure Material: ABS
Enclosure Dimensions (h x w x d): 230 x 180 x 100 mm
Unit Weight: 2.7 kg
Busbar Material: Tinned copper
Busbar Dimensions (h x w): 8 x 30 mm
Environmental Specifications:
Operating Temperature Range: -40 °C to +60 °C
Storage Temperature Range: -40 °C to +60 °C
Humidity Max.: 95 % (non-condensing)
Protection Class: IP22
Standards
Safety: EN-IEC 63000:2018
EMC: EN-IEC 61000-6-3:2007/A1:2011/AC:2012
QMS: NEN-EN-ISO 9001:2015
Please contact your dealer for any returns, repairs or support issues related to this product.
|
1499.40 |
|
|
Fuse Block Class T 225-400 AMP
Part #: 5502
Features:
Maximum Voltage: 160 Volts DC
Maximum Amperage: 400 Amperes DC
Maximum Torque: 190 in-lb (21.47 Nm) max.
Terminal Stud Size: 3/8"-16 (M10)
Mounting Holes: Accept 1/4" (M6) Screw
Maximum Cable Size 4/0 AWG
Fuse Mounting Blocks: Tin-Plated Copper
Class T Fuses Available: 110-400 Amperes DC
Fuse Sold Sepereatly
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
47.47 |
|
|
Class T Fuse Holder with 2 Additional Studs 225-400A
Providing high-capacity fusing, fast response and very high interrupt ratings (ANL up to 6,000 Amps, Class-T up to 20,000 Amps), these fuse holders are ideal for protecting today's demanding onboard power electronics technology including inverters and battery chargers. They also protect wiring from short circuits. Pro Installer fuse holders' durable construction allow fuses to run at maximum load.
Radiused ends improve cable routing options
Class-T: 225-400 Amp
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
50.47 |
|
|
Class T Fuse Holder with 2 Additional Studs 450-600A
Providing high-capacity fusing, fast response and very high interrupt ratings (ANL up to 6,000 Amps, Class-T up to 20,000 Amps), these fuse holders are ideal for protecting today's demanding onboard power electronics technology including inverters and battery chargers. They also protect wiring from short circuits. Pro Installer fuse holders' durable construction allow fuses to run at maximum load.
Radiused ends improve cable routing options
Class-T: 450-600 Amp
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
59.23 |
|
|
Class T Fuse Block with Insulating Cover - 225 to 400A
Allows the use of Class T fuses for fast acting circuit protection of inverters and other electronics
Four stud design provides ample access around connecting stud to install large cable lugs without obstruction from the fuse
Insulating cover satisfies ABYC/USCG insulation requirements
Cover breakouts allow wire access in any direction
Stud design ensures secure fuse mounting even with high heat
Stainless steel studs provide resistance to corrosion and high torque
One-piece stainless flange nuts ensure safe and secure connections
UL 94-V0 base resists high heat
Technical Specifications:
Cable Size: Up to 4/0 AWG
Ignition Protected: Yes
Maximum Amperage: 320A
Maximum Voltage: 160V DC
Fuse Mounting Blocks: Tin-Plated Copper
Terminal Stud Size: 5/16"-18 (M8)
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
68.44 |
|
|
5118 250AMP Class T Fuse
Features:
Extremely fast short-circuit response
20,000 Ampere Interrupt Capacity (AIC)
UL listed to standard 248-15
DC Tested to UL standard 198L
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
39.78 |
|
|
Class T Fuse Block with Insulating Cover - 110 to 200A
Allows the use of Class T fuses for fast acting circuit protection of inverters and other electronics
Four stud design provides ample access around connecting stud to install large cable lugs without obstruction from the fuse
Insulating cover satisfies ABYC/USCG insulation requirements
Cover breakouts allow wire access in any direction
Stud design ensures secure fuse mounting even with high heat
Stainless steel studs provide resistance to corrosion and high torque
One-piece stainless flange nuts ensure safe and secure connections
UL 94-V0 base resists high heat
Specifications:
Cable Size: Up to 4/0 AWG
Ignition Protected: Yes
Maximum Amperage: 200A
Maximum Voltage: 160V DC
Fuse Mounting Block: Tin-Plated Copper
Terminal Stud Size: 5/16"-18 (M8)
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
68.44 |
|
|
5112 110A Class T Fuse
Features:
Extremely fast short-circuit response
20,000 Ampere Interrupt Capacity (AIC)
UL listed to standard 248-15
DC Tested to UL standard 198L
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
39.78 |
|
|
5113 125A Class T Fuse
Features:
Extremely fast short-circuit response
20,000 Ampere Interrupt Capacity (AIC)
UL listed to standard 248-15
DC Tested to UL standard 198L
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
39.78 |
|
|
5116 200A Class T Fuse
Features:
Extremely fast short-circuit response
20,000 Ampere Interrupt Capacity (AIC)
UL listed to standard 248-15
DC Tested to UL standard 198L
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
39.78 |
|
|
5117 225AMP Class T Fuse
Features:
Extremely fast short-circuit response
20,000 Ampere Interrupt Capacity (AIC)
UL listed to standard 248-15
DC Tested to UL standard 198L
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
39.78 |
|