Submersible Pressure Transducer 0-3 PSI
Maretron’s submersible pressure transducers indicate tank levels and can be installed directly in the tank. Please follow these instructions to mount and connect a submersible pressure transducer to an NMEA 2000® network via a Maretron FPM100 Fluid Pressure Monitor. Maretron recommends one of two methods for mounting a submersible pressure transducer in a tank: 1) without a restraining tube, and 2) with a restraining tube.
The submersible pressure transducers are designed for a tank with a 5-hole SAE J1810 fitting at the top. Install the mounting plate with cord grip onto the transducer cable, with the rounded hex section of the cord grip facing away from the transducer.
Lower the pressure transducer into the tank such that the transducer lies at the lowest point of the tank and tighten the cord grip to secure the cable. On a tank with a flat bottom, the transducer may slide from side to side with the motion of the vessel but will not rotate due to the stiffness of the cable. It is also possible to mount the pressure transducer inside a restraining or focus tube (sold separately, Maretron part number TFT-5H).
Pressure Transducer Mounting
Connect the two wires of the pressure transducer to a free pressure monitoring channel. Connect the red wire from the pressure transducer to the channel's positive (+) terminal and connect the black wire from the pressure transducer to the negative (-) terminal of the channel. The example in Figure 1 shows the pressure transducer connected to switch channel 0, with the white wire connected to "P0+" and the brown wire connected to "P0-." Submersible pressure transducers have a small plastic vent tube in the connecting cable.
Use a Maretron DSM Series Display (firmware 1.4.7 or higher) or a PC running Maretron’s N2KAnalyzer software (version 1.4.19 or higher) to configure the connected channel(s) on the FPM100.
Supply power to the NMEA 2000 network and verify that the pressure channel indicates a valid pressure reading.
Specifications:
Operating Range: 0 to 3 PSI (0.207 bar)
Depth Range (Water): 83.1” (2.11 m)
Depth Range Diesel (820 kg/m3): 101.3” (2.57 m)
Depth Range Gasoline/Petrol (750 kg/m3): 110.8” (2.81 m)
Cable Length: 17 ft (5.18 m)
Sensor Type: Gauge (Vent Tube)
Output: 4 – 20 mA current loop, loop powered
Excitation Voltage: 8 VDC to 28 VDC
Compatible Fluids / Gases: Diesel, Diesel Exhaust Fluid (DEF), Gasoline/Petrol, Hydraulic Fluid, Kerosene, Motor Oil, Fresh Water, Sea Water, Waste Water
Operating Temperature: 14 degrees F to 158 degrees F (-10 degrees C to 80 degrees C)
Storage Temperature: -4 degrees F to 176 degrees F (-20 degrees C to 80 degrees C)
Accuracy: ±0.3% Full Scale typ. at 25°C
Total Error Band (TEB): ±1.0% Full Scale typ. (-10 degrees C to 70 degrees C)
Non-Linearity, Hysteresis (NLH): ±0.2% Full-Scale typ. Best Straight Line (BSL) at 25°C
Temperature Compensation: 23 degrees F to 122 degrees F (0 degrees C to 50 degrees C)
Accuracy: ±1% Full Scale
Linearity: 0.5% Full Scale
Repeatability: 0.05% Full Scale
Full-Scale Thermal Error: 0.04% Full Scale/°F (0.07% Full Scale/degrees C)
Long-Term Stability: 0.2% Full Scale/year
Response Time: 150ms
Proof Pressure: 2 × Full Scale
Burst Pressure: 3 × Full Scale
Reverse Voltage Protection: ± 30V for 3 minutes
Construction: 316L stainless steel body and diaphragm, polyether polyurethane cable, chloroprene boot
EMC Compatibility: 10 Volts/meter per EN 61000-4-3
Weight: 24.8oz (703g)
|
393.12 |
|
|
Submersible Pressure Transducer - 0 to 5 PSI
The submersible pressure transducers are used together with Maretron's Fluid Pressure Monitor (FPM100), whichallows tank fluid level to be broadcast over an NMEA 2000® network where it can be monitored from any compatible NMEA 2000® display. When used together with Maretron displays, alerts can be set so the user can be informed of low or high tank levels. And when not on-board the vessel, users can be notified through emails or text messages about theirtank levels. Additionally, the tank levels can be stored using Maretron's data recorder (VDR100) for later analysis.
WARNING: This product can expose you to chemicals including NICKEL (METALLIC) which is known to the State of California to cause cancer. For more information go to P65Warnings.ca.gov.
|
433.92 |
|
|
Submersible Pressure Transducer - 0-1.5 PSI
The submersible pressure transducers are used together with Maretron's Fluid Pressure Monitor (FPM100), which allows tank fluid level to be broadcast over an NMEA 2000® network where it can be monitored from any compatible NMEA 2000® display. When used together with Maretron displays, alerts can be set to inform the user of low or high tank levels. Users can be notified through emails or text messages about their tank levels when not onboard the vessel. Additionally, the tank levels can be stored using Maretron's data recorder (VDR100) for later analysis.
|
284.16 |
|
|
Galley Maid Pressure Gauge 0-60 PSI
Picture is a representation of a 0 to 60 PSI gage.
|
37.80 |
|
|
Pressure Transducer - 0 to 5000 PSI
This pressure transducer is designed to connect to the NMEA 2000® network via a Maretron FPM100 Fluid Pressure Module.
Specifications:
Range: 0 to 5000 PSI (344.74 bar)
Accuracy: +/- 0.5% Full Scale
Type: Absolute (no vent tube)
Installation:
All Maretron pressure transducer assemblies are equipped with a 1/4 in. NPT male threaded fitting. Install the pressure transducer to a 1/4 in. NPT female fitting on the system or tank is to be monitored with a maximum torque of 150 in-lbs (16.95 Nm).
If you are monitoring a system where pressure spikes or transients will occur, or where the pressure will exceed the maximum pressure rating of the pressure transducer, install a Pressure Snubber (PT-SNUB-01) onto the system being monitored first, then install the pressure transducer to the female port on the pressure snubber.
|
220.75 |
|
|
Pressure Transducer 0 to 50 PSI
All Maretron pressure transducer assemblies are equipped with a 1/4” NPT male threaded fitting. Install the pressure transducer to a ¼” NPT female fitting on the system or tank to be monitored with a maximum torque of 150 in-lbs (16.95 Nm). If you are monitoring a system where pressure spikes or transients will occur, or where the pressure will exceed the maximum pressure rating of the pressure transducer, install a Pressure Snubber (PT-SNUB-01) onto the system being monitored first, then install the pressure transducer to the female port on the pressure snubber.
WARNING: This product can expose you to chemicals including NICKEL (METALLIC) which is known to the State of California to cause cancer. For more information go to P65Warnings.ca.gov.
|
194.88 |
|
|
Pressure Transducer 0 to 5 PSI - for FPM100 Fluid Pressure Monitor
WARNING: This product can expose you to chemicals including NICKEL (METALLIC) which is known to the State of California to cause cancer. For more information go to P65Warnings.ca.gov.
|
181.44 |
|
|
Pressure Transducer 0 to 1.5 PSI
For use with FPM100 Fluid Pressure Monitor
WARNING: This product can expose you to chemicals including NICKEL (METALLIC) which is known to the State of California to cause cancer. For more information go to P65Warnings.ca.gov.
|
181.44 |
|
|
Pressure Transducer 0 to 3 PSI - for the FPM100 Fluid Pressure Monitor
WARNING: This product can expose you to chemicals including NICKEL (METALLIC) which is known to the State of California to cause cancer. For more information go to P65Warnings.ca.gov.
|
153.60 |
|
|
2" Oil Pressure Gauge (0-100 PSI)
A pressure gauge operates by sending a low amperage current through the gauge's meter to ground via a sending unit with variable resistance. The resistance of the sending units increase or decrease with the changes in pressure, temperature, etc...
As the sender's resistance varies, the amount of current allowed to flow through it to ground changes and the meter deflects, showing the change in pressure.
Includes fire orange pointer, black aluminum bezel, flat glass lens, case with locator keyway to ensure proper installation and perimeter lighted black dial with stylish white graphics.
Available for MG systems, J1939 CAN Bus or J1939 Stand-Alone systems and mechanical types.
2" - Hole Size: 2.0625" (53mm)
Specifications:
Standard (100-200°F)
Scratch Resistant Lens
Black Aluminum Bezel
Orange Contoured Pointer
|
14.79 |
|
|
Jabsco 30472-1000 Pressure Gauge 0-60 Psi
|
5.06 |
|
|
Newport SS 2" Oil Pressure Gauge - 0 to 80 PSI
The Newport Stainless Steel (SS) family of marine gauges is a classic style of gauge, engineered to be the new Modern Retro.
Designed with the latest fog resistant features, this Retro Style gauge far surpasses all expectations. Perimeter lighting makes reading these gauges easy to read Day/Night.
Features:
Perimeter lighted Retro White Dial
Black and Gray Graphics
Domed fog resistant lens
Two-piece Black pointers
Hand-polished Stainless Steel bezel
Studded connection for ring terminals
Red illuminated edge-lighting
Technical Specifications:
Operating Range - 0 to 80 PSI
2.06" (53 mm) Mounting hole
Operating Voltage - 12/24 V
In the box:
Gauge
Mounting Hardware
Installation Manual
Factory P/N GP8159
*Sold as an Individual
**Gauge Cover not Included
This product may not be returned to the original point of purchase. Please contact the manufacturer directly with any issues or concerns.
|
42.36 |
|
|
Par-Max 3 Water Pressure Pump - 12V - 3 GPM - 25 PSI
HD (Heavy Duty) models include a wider diameter motor with a powder coated shell, cast aluminum endbells and lower housing to improve pressure capability and life. Available in configurations up to 6 GPM (23 LPM) and 60 PSI (4.1 BAR), these pumps deliver exceptional performance.
Standard models provide good performance in an economical footprint. These configurations are available in 1-3 GPM, perfect for vessels with 1-3 outlets. A plastic housing protects the motors on these units from corrosion.
Features:
Co-molded diaphragm technology for long life and durability
HD models feature heavy duty, motors and cast aluminum lower housings which allow for longlife, even at high pressures
Efficient and quiet operation
Integrated, sealed pressure switch for on-demand operation
Self-priming allows for installation versatility
Can run dry without damage
Quick connect ports for ease of installation, servicing, and maintenance
Vibration dampening mounting feet
Equipped with integrated bypass module to reduce cycling and provide smoother flow
Specifications:
Motor design: Brushed, permanent magnet TENV
Pumphead upper housing material: Glass fiber reinforced polypropylene
Diaphragm: Co-molded TPV
Check valves: EPDM
Max inlet pressure: 30 PSI (2.1 Bar)
Fluid temperature range: 32°F – 140°F (0°C – 60°C)
Dry self-priming capability: 7ft min (2.13m/min)
Certifications: CE, ISO8846, RCM
Ingress Protection: IPX6
WARNING: This product can expose you to chemicals including ANTIMONY OXIDE (ANTIMONY TRIOXIDE) which is known to the State of California to cause cancer. For more information go to P65Warnings.ca.gov.
|
117.98 |
|
|
Par-Max 3 Water Pressure Pump - 12V - 3 GPM - 40 PSI
HD (Heavy Duty) models include a wider diameter motor with a powder coated shell, cast aluminum endbells and lower housing to improve pressure capability and life. Available in configurations up to 6 GPM (23 LPM) and 60 PSI (4.1 BAR), these pumps deliver exceptional performance.
Standard models provide good performance in an economical footprint. These configurations are available in 1-3 GPM, perfect for vessels with 1-3 outlets. A plastic housing protects the motors on these units from corrosion.
Features:
Co-molded diaphragm technology for long life and durability
HD models feature heavy duty, motors and cast aluminum lower housings which allow for longlife, even at high pressures
Efficient and quiet operation
Integrated, sealed pressure switch for on-demand operation
Self-priming allows for installation versatility
Can run dry without damage
Quick connect ports for ease of installation, servicing, and maintenance
Vibration dampening mounting feet
Equipped with integrated bypass module to reduce cycling and provide smoother flow
Specifications:
Motor design: Brushed, permanent magnet TENV
Pumphead upper housing material: Glass fiber reinforced polypropylene
Diaphragm: Co-molded TPV
Check valves: EPDM
Max inlet pressure: 30 PSI (2.1 Bar)
Fluid temperature range: 32°F – 140°F (0°C – 60°C)
Dry self-priming capability: 7ft min (2.13m/min)
Certifications: CE, ISO8846, RCM
Ingress Protection: IPX6
WARNING: This product can expose you to chemicals including ANTIMONY OXIDE (ANTIMONY TRIOXIDE) which is known to the State of California to cause cancer. For more information go to P65Warnings.ca.gov.
|
117.98 |
|
|
Pressure Relief Valve - 75 PSI
Water Heater Pressure Relief valve. Water heater temperature and pressure relief valves, or T&P valves, are a safety feature found on all tank water heaters. It's designed to open temporarily and discharge short spurts of water when the temperature exceeds about 210 degrees F, and it releases pressure if the tank gets above 75 psi.
WARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
44.62 |
|