8079 AC Main Only Circuit Breaker Panel - White Switches
Features:
Red reverse polarity indicating LED
Safety ground screw on panel back
Combines switching and circuit protection into a single device
"Trip Free" design cannot be held "ON" during fault current condition
Specifications:
Nominal Voltage: 120v AC
Maximum Voltage: 277v AC / 65v DC
Height: 2.63"
Width: 3.75"
Weight: 0.51 lbs
Includes
(1) 8034 LED - 120v AC Green
(1) 8066 LED - 120v AV Red
(1) 7242 A-Series White Toggle Circuit Breaker - Double Pole 50A (Main)
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
104.30 |
|
|
8027 AC Main +6 Position Breaker Panel - White Switches
Features:
Red reverse polarity indicating LED
All hot, neutral and safety ground buses installed, fully pre-wired
All circuit label positions are backlit on standard panels - No kit required
"ON" indicating LEDs installed in all circuit positions
Specifications:
Positions: 6
Nominal Voltage: 120v AC
Height: 7.5"
Width: 5.25"
Included:
(1) 8031 Basic AC Panel Label Set - 30 Labels
(7) 8034 LED - 120v AC Green
(1) 8066 LED - 120v AC Red
(3) 7210 A-Series White Toggle Circuit Breaker - Single Pole 15A (Branch)
(1) 7238 A-Series White Toggle Circuit Breaker - Double Pole 30A (Main)
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
236.45 |
|
|
8029 AC Main +1 Position Breaker Panel - White Switches
Features:
Red reverse polarity indicating LED
All hot, neutral and safety ground buses installed, fully pre-wired
All circuit label positions are backlit on standard panels - No kit required
"ON" indicating LEDs installed in all circuit positions
Specifications:
Positions: 1
Nominal Voltage: 120v AC
Height: 3.75"
Width: 5.25"
Included:
(2) 8034 LED - 120v AC Green
(1) 8066 LED - 120v AC Red
(1) 7238 A-Series White Toggle Circuit Breaker - Double Pole 30A (Main)
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
127.01 |
|
|
8084 AC Main +6 Positions/DC Main +15 Positions Toggle Circuit Breaker Panel - White Switches
Features:
Includes set of 30 common AC and 30 common DC labels
All AC and DC buses installed, fully pre-wired
Label backlighting pre-installed
All LEDs installed
Maximum panel Amperage: 100 Amperes DC / 50 Amperes AC
AC Features:
Red reverse polarity indicating LED
Ready for installation of optional 4029 AC Isolation Cover
9353, 0-150 Volt AC Voltmeter
DC Features:
100 Amp C-Series circuit breaker provides main circuit protection and switching for DC branch circuits
8003, 8-16 Volt DC Voltmeter
8017, 0-100 Amp DC Ammeter
Owner upgradeable to 24 Volts with 8240, 18-32 Volt DC Voltmeter
Specifications:
AC Positions: Main +6
DC Positions: Main +15
120 Volts AC
12 Volts DC
(1) 30A - (3) 15A AC Circuit Breakers
(1) 100A - (9) 15A DC Circuit Breakers
*Combined AC/DC panels require a AC Insulating Cover to meet ABYC Standards
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
915.92 |
|
|
8086 AC 3 Sources +12 Positions/DC Main +19 Position Toggle Circuit Breaker Panel - White Switches
Features:
Includes set of 30 common AC and 30 common DC labels
All AC and DC buses installed, fully pre-wired
Label backlighting pre-installed
All LEDs installed
Maximum panel Amperage
100 Amperes DC
50 Amperes AC
AC Features:
Two separate AC load groups with transfer switch to combine into one load group
Switch allows Ammeter and Voltmeter to read either AC load group
Reverse polarity indicators on both AC load groups
Ready for installation of optional 4031 AC Isolation Cover
9353, 0-150 Volt AC Voltmeter
9630, 0-50 Amp AC Ammeter
DC Features:
100 Amp C-Series circuit breaker provides main circuit protection and switching for DC branch circuits
8003, 8-16 Volt DC Voltmeter
8017, 0-100 Amp DC Ammeter
Specifications:
AC Positions: Source Selectors +12
DC Positions: Main +19
120 Volts AC
12 Volts DC
(3) 30A - (1) 50A - (6) 15A AC Circuit Breakers
(1) 100A - (13) 15A DC Circuit Breakers
*Combined AC/DC panels require a AC Insulating Cover to meet ABYC Standards
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
1612.97 |
|
|
8076 AC Main +11 Positions Toggle Circuit Breaker Panel - White Switches
Features:
Red reverse polarity indicating LED
All hot, neutral and safety ground buses installed, fully pre-wired
All circuit label positions are backlit on standard panels - No kit required
"ON" indicating LEDs installed in all circuit positions
Specifications:
Positions: 11
Nominal Voltage: 120v AC
Height: 7.5"
Width: 10.5"
Included:
(1) 8031 Basic AC Panel Label Set - 30 Labels
(12) 8034 LED - 120v AC Green
(1) 8066 LED - 120v AC Red
(8) 7210 A-Series White Toggle Circuit Breaker - Single Pole 15A (Branch)
(1) 7238 A-Series White Toggle Circuit Breaker - Double Pole 30A (Main)
(1) 8244 AC Micro Voltmeter - 0 to 150v AC (Meter)
(1) 8246 AC Micro Ammeter - 0 to 50A w/ Coil (Meter)
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
577.72 |
|
|
8043 AC Main +3 Positions Toggle Circuit Breaker Panel - White Switches
Features:
Red reverse polarity indicating LED
All hot, neutral and safety ground buses installed, fully pre-wired
All circuit label positions are backlit on standard panels - No kit required
"ON" indicating LEDs installed in all circuit positions
Specifications:
Positions: 3
Nominal Voltage: 120v AC
Height: 7.5"
Width: 5.25"
Included:
(1) 8031 Basic AC Panel Label Set - 30 Labels
(4) 8034 LED - 120v AC Green
(1) 8066 LED - 120v AC Red
(3) 7210 A-Series White Toggle Circuit Breaker - Single Pole 15A (Branch)
(1) 7238 A-Series White Toggle Circuit Breaker - Double Pole 30A (Main)
(1) 9353 AC Voltmeter - 0 to 150v AC (Meter)
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
281.88 |
|
|
8074 AC Main +8 Positions Toggle Circuit Breaker Panel - White Switches
Features:
Red reverse polarity indicating LED
All hot, neutral and safety ground buses installed, fully pre-wired
Label backlighting pre-installed
All LEDs installed
9353, 0-150 Volt AC Voltmeter
9630, 0-50 Amp AC Ammeter
Maximum panel Amperage - 50 Amperes
1 30A Double Pole Circuit Breaker
5 15A Single Pole Circuit Breakers
120 Volt
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
478.27 |
|
|
8097 AC 6 Position Toggle Circuit Breaker Panel - White Switches
Features:
All hot, neutral, and safety ground buses installed, fully pre-wired
All circuit label positions are backlit on standard panels - No kit required
"ON" indicating LEDs installed in all circuit posistions
Maximum panel amperage - 100 Amperes
Specifications:
Positions: 6
Nominal Voltage: 120v AC
Maximum Amperage: 100a
Height: 3.75"
Width: 10.5
Included:
(6) 7210 A-Series White Toggle Circuit Breaker - Single Pole 15A
(1) 8031 Basic AC Panel Label Set - 30 Labels
(6) 8034 LED - 120v AC Green
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
259.62 |
|
|
8058 AC 3 Position Toggle Circuit Breaker Panel - White Switches
Features:
All hot, neutral, and safety ground buses installed, fully pre-wired
All circuit label positions are backlit on standard panels - No kit required
"ON" indicating LEDs installed in all circuit posistions
Maximum panel amperage - 100 Amperes
Specifications:
Positions: 3
Nominal Voltage: 120v AC
Maximum Amperage: 100A
Height: 3.75"
Width: 5.25"
Included:
(3) 7210 A-Series White Toggle Circuit Breaker - Single Pole 15A
(1) 8031 Basic AC Panel Label Set - 30 Labels
(3) 8034 LED - 120V AV Green
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
158.08 |
|
|
8068 DC 13 Position Toggle Branch Circuit Breaker Panel - White Switches
Features:
All positive, negative and grounding buses installed, fully pre-wired
Includes set of 30 common DC labels
Label backlighting pre-installed
All LEDs installed
Detailed installation instructions and cutout template
8028, 8-16 Volt DC Micro Voltmeter
8041, 0-50 Amp DC Micro Ammeter
10 15A Single Pole Circuit Breakers
Toggle Branch Circuit Breaker Panel
Specifications:
Positions: 13
Nominal Voltage: 12v DC
Maximum Amperage: 50A
Height: 7.5"
Width: 10.5"
Depth: 3"
Weight: 4.2 lbs
Included:
(10) 7210 A-Series White Toggle Circuit Breaker - Single Pole 15A
(1) 8030 Basic DC Panel Label Set - 30 Labels
(1) 8028 DC Micro Voltmeter - 8 to 16v DC (Meter)
(1) 8041 DC Micro Ammeter - 0 to 50A w/ Shunt (Meter)
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
578.66 |
|
|
8081 DC 5 Position Toggle Branch Circuit Breaker Panel - White Switches
Features:
All positive, negative and grounding buses installed, fully pre-wired
Panels with meters include toggle switch for mounting up to 3 battery banks
All panels with analog meters are owner upgradable to 24 Volts with 8240 or 8243 (18-32V DC meters)
All circuit label positions are backlit on standard panels - No kit required
"ON" indicating LEDs installed in all circuit positions
Specifications:
Positions: 5
Nominal Voltage: 12v DC
Maximum Amperage: 50A
Height: 7.5"
Width: 5.25"
Depth: 2.5"
Weight: 2.25 lbs
Included:
(5) 7210 A-Series White Toggle Circuit Breaker - Single Pole 15A
(1) 8030 Basic DC Panel Label Set - 30 Labels
(1) 8041 DC Micro Ammeter - 0 to 50A w/ Shunt (Meter)
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
367.52 |
|
|
8096 DC 6 Position Toggle Branch Circuit Breaker Panel - White Switches
Features:
All positive, negative and grounding buses installed, fully pre-wired
Panels with meters include toggle switch for mounting up to 3 battery banks
All panels with analog meters are owner upgradable to 24 Volts with 8240 or 8243 (18-32V DC meters)
All circuit label positions are backlit on standard panels - No kit required
"ON" indicating LEDs installed in all circuit positions
Specifications:
Positions: 6
Nominal Voltage: 12v/24v
Maximum Amperage: 100A per bus
Height: 3.75"
Width: 10.5"
Depth: 2.5"
Included:
(6) 7210 A-Series White Toggle Circuit Breaker - Single Pole 15A
(1) 8030 Basic DC Panel Label Set - 30 Labels
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
270.88 |
|
|
AC Main +4 Positions
PN: 8099
White Switches
Features
Red reverse polarity indicating LED
All hot, neutral and safety ground buses installed, fully pre-wired
Label backlighting pre-installed
All LEDs installed
Maximum panel Amperage - 50 Amperes
(1) 30A Double Pole Circuit Breaker
(4) 15A Single Pole Circuit Breaker
120 Volt
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
273.04 |
|
|
AC Main +8 Positions / DC Main +29 Positions
PN: 8095
White Switches
Includes set of 30 common AC and 30 common DC labels
All AC and DC buses installed, fully pre-wired
Label backlighting pre-installed
All LEDs installed
Maximum panel Amperage
100 Amperes DC
50 Amperes AC
AC Features
Red reverse polarity indicating LED
9353, 0-150 Volt AC Voltmeter
9630, 0-50 Amp AC Ammeter
DC Features
100 Amp C-Series circuit breaker provides main circuit protection and switching for DC branch circuits
8003, 8-16 Volt DC Voltmeter
8017, 0-100 Amp DC Ammeter
Owner upgradeable to 24 Volts with 8240, 18-32 Volt DC Voltmeter
Specifications:
AC Positions: Source Selectors +8
DC Positions: Main +29
120 Volts AC
12 Volts DC
(1) 30A - (5) 15A AC Circuit Breakers
(1) 100A - (20) 15A DC Circuit Breakers
Combined AC/DC panels require a AC Insulating Cover to meet ABYC Standards
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.
|
1459.26 |
|